Dry-Matic DM01D Manuale di istruzioni per l'uso - Pagina 11

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Regolatore di temperatura Dry-Matic DM01D. Dry-Matic DM01D 16. Digital controller

Dry-Matic Set up Commissioning Instructions
Menu sequence is as follows. Press up and down arrow together to get to Setu p Menu.
Press up (or down) button to change setting, then press Mode to enter desired setting.
1. Heater Kit
Y/N (default Y) For DM01 press up arrow to change to N - this will remove
heater options from all menus (heater options in orange). Press Mode to select.
1.2 Heater Times
> display then changes to show the current settings default:
Heater on 00:00
Heater off 00
> display then changes again to Change times Y/N (default N)
Select desired 'Heater ON' time in Hours:Mins using up or down arrow, press mode to select
Select desired 'Heater OFF' time in Hours:Mins using up or down arrow, press mode to select.
Y/N (default N)
1.3 Heater Test
2. Max Fan S p eed
(default 35%) range 35-60
Provides the ability to adjust fan Hi speed to suit the size of the house. We recommend:
35% for houses up to 150m
40% for houses up to 200m
45% for houses up to 250m
50% for houses up to 300m
For houses larger than this we recommend additional Dry-Matic units.
3. Min Fan S p eed
(default 25%) range 20-35
Provides the ability to adjust fan minimum speed, we recommend a setting of 25% for this.
4. Fan S p eed Heat
(default 32%) range 30-45
This must be set to ensure that minimum speed is sufficient to ensure heater sail switch
operates (with semi dirty filter) and provides sufficient airflow to the number of outlets
installed, balanced against too much airflow that will limit temperature rise through the
heater.
- Adjustment range 30-45%
- At default setting, nominal temp rise is 9°C for DM07
- At default setting, nominal temp rise is 18°C for DM15. We recommend Fan Speed Heat
set at 30% for this model.
- If "heater fault" appears only briefly, this is normal
5. Winter mode
Y/N (default Y) - Winter shutdown mode (up button to change to Y, Mode to
enter). This setting is available for particularly cold locations, and is mainly when house is
not heated (house unoccupied for periods of days or weeks), as in these conditions, when
moist outside air is introduced, in some cases it can cause worse air quality, resulting in
condensation.
If 'Y': if attic temp (T
again. If 'Y', next menu is:
5.1 S/down tem p ?
enter).
6. Summer-Vent Inst
If 'Y' & summer vent kit is installed, the fan can be operated at full speed and the duct
diverting damper set to draw air from outside (cool side of the house) for 2, 4, 8, 12,
24hrs or 'off', by pressing the up arrow when in operating mode (not in any menu).
DM - Operating Instructions, Installation Instructions, Wiring diagrams
(option only for heated models)
(option only for heated models)
2
(requires at least a second grille)
2
(requires at least a second grille)
2
(requires at least a second grille)
2
) is less than 0°C (default), the system shuts down until T
A
(default 0°C, range: -2° to +2°C ) (up & down arrows to change, mode to
(default N) (up button to change to Y, mode to enter)
(option only for heated models)
Note - if heater faults during commissioning,
please check heater is installed level.
(continued)
increases
A
continued on next page
Version 3.1.765 August 2019
11