1. Unit is sized for 250dm @ max 200psi. Optimal performance will be achieved at operating pressures
above 90psi.
2. Connect unit to portable battery using either the alligator clip or ring terminal adaptors which are
supplied with the unit. Make sure polarity is correct to have DC fan move air through the heat
exchanger toward the fan motor. Route power cord up through the bottom of the compressor to the
battery being careful not to pinch or chafe wires.
3. The integral pressure switch will keep the fan from operating until the unit is pressurized.
4. The air inlet connection is at the top of the cooler, marked on the top rail.
5. The outlet ball valve is located downstream from the water separator and filter and is also marked
on the top rail.
6. Close the ball valve on the unit when first pressurizing to allow the pressure to equalize around the
filter element. When the unit is pressurized open gradually to fill hose.
7. Slightly open the manual drain on both the separator and filter to allow water to drain during
operation. These drain valves are marked with green tags.
8. Condensate can be captured in some type of collection tray, not provided in DryAIR package, or
piped away into a collection container depending on individual job site requirements.
9. The brass low point drain, marked with a red tag, should remain closed during normal
valve is intended to be used to prevent freeze ups in cold temperatures or otherwise drain the unit
after use.
250FS (Free Standing)
WEIGHT: 80 LBS.
WIDTH: 24"
DEPTH: 19"
HEIGHT: 32"
FAN AMPS: 12V 19.4 AMPS/24V 9.7 AMPS
FUSE: 30 AMPS
*To install
tongue mounted
U
with
bolts.•
How it works:
TDM DryAIR aftercoolers are air to air heat exchangers that remove the heat of compression from portable air
compressor discharge air. In this process moisture Is condensed and collected in a cyclone separator to be drained
from the compressed air stream. If the unit is equipped with an optional coalescing filter, further polishing is
accomplished by trapping oil, in the form of aerosols, which are drained as well.
coalescing filter rarely, if ever, will require replacement due to its location in the system. The "service indicator''
on the filter will alert you If necessary.
What it will NOT do:
TDM DryAIR aftercoolers in themselves will NOT produce breathing air. They are the first step in the process but
need additional components to assure breathing air quality and monitoring.
Sold by General Machine Products (KT), LLC 3111 Old Lincoln Hwy Trevose PA 19053
r
�iijiiiii
i)
UNIT SPECIFICATIONS
250UTM (Universal Tongue Mount)
units
unit
simply straddle
securely over the tongue and attach clamp
REV 3 5/14/15/15
215-357-5500 www.gmptools.com
· .•
4••
-i, i
WEIGHT: 65 LBS
WIDTH: 30"
DEPTH 14"
30"
HEIGHT
FAN AMPS: 12V 19.4 AMPS/24V 9.7 AMPS
FUSE: 30
AMPS
*Note:
operation.
This