Anolis ArcWash Recessed 136 RGB Manuale d'uso - Pagina 16
Sfoglia online o scarica il pdf Manuale d'uso per Apparecchiature di illuminazione Anolis ArcWash Recessed 136 RGB. Anolis ArcWash Recessed 136 RGB 19. Rgb
3.It is recommended that you exit all programs before running the Software Uploader.
4.Start the Software Uploader program. Select desired COM and then click Connect button.
If the conection is OK, click Start Uploading button to start uploading. It will take several minutes to
perform software update. If the option "Incremental Update"isn´t checked ,all processors will be
updated (including processors with the same software version).
If you wish to update only later versions of processors, enable the Incremental Update check box.
Avoid interrupting the process. Update status is being displayed in the list window.
When the update is finished, the line with the text "The fixture is successfuly updated' will appear in
this window and the fixture will reset with the new software.
Note: In the case of interruption of the upload process (e.g. power cut), the fixture remains in the update mode and you
have to repeat the software update again.
For example: The fixture was switched off before finishing software upload. After switching the fixture on again, the fixture
is still in the update mode and the display is dark. Restart the Software Uploader program and repeat software update
from your PC.
This mode omits fixture reset after switching the fixture on and lowers motor powers of the fixture. „Power down mode"
is useful in special casech. g. if the fixture is in a flight case and you want to set its DMX address without taking it out
from the case. To enter „Power down mode", press and hold [UP] and [DOWN] and at the same time switch on the Power
switch. The following message appears on the display: "P.d.Mo."
Press [ENTER] to activate „Low power mode" without fixture reset. Now you can set features and behaviour of the fixture
by using "Pers." menu. If you want to go „normal operation mode", execute fixture reset.
Note: All motors in "Power down mode" are deactivated.
PA.Er. (Pan-yoke movement error)
This message will appear after the reset of the fixture if the yoke's magnetic-indexing circuits malfunction (sensors failed
or magnet missing) or the stepping motor is defective. (Or its driving IC on the main PCB). The yoke is not located in the
default position after the reset.
ti.Er. (TILT-head movement error)
This message will appear after the reset of the fixture if the head's magnetic-indexing circuit malfunctions (sensor failed
or magnet missing) or the stepping motor is defective. (Or its driving IC on the main PCB). The head is not located in the
default position after the reset.
8. Power down mode
9. Error and information messages