This device falls under protection class I.Therefore the ArcPower Micro 270 has to
be connected to a mains socket outlet with a protective earthing connection.

5.Installing instructions.

5.1.Mounting the ArcPower Micro 270
The ArcPower Micro 270 should be be placed on a non-f lammable f lat surface in any orientation and fixed by
the screws.There are 6 mounting holes of 5x7 mm in housing of the driver.

5.2.Conection cables

1.The adapter cable RJ45/XLR connects the ArcPower Micro 70 to the DMX controller.If your DMX controller
has RJ45 socket for DMX output,use RJ45 patch cable for connection with the ArcPower Micro 70.
RJ45 plug
View facing pins
Pin 1: Not used
Pin 2: Not used
Pin 3: Not used
Pin 4: Not used
Pin 5: +5V
Pin 6: Data +
Pin 7: Data -
Pin 8: GND
2.RJ45 patch cables category 5 that connect the ArcPower Micro 70 each other are wired 1:1,that is,pins with
the same numbers are connected together.
Pin 1: Not used
Pin 2: Not used
Pin 3: Not used
Pin 4: Not used
Pin 5: +5V
Pin 6: Data +
Pin 7: Data -
Pin 8: GND
5.3.Interconnecting the ArcPower Micro 270 and ArcLine Micro 36
The ArcPower Micro 70 is equipped two wiring blocks for easy connection of ArcLine Micro 36 modules.The
wiring blocks are wired in paralel.The power/data cable for connection of LED module is included and its wiring
is as follows:
ArcPower Micro 70
DMX 512 XLR plug (male)
Front view of the plug
Pin 1: GND
Pin 2: Data -
Pin 3: Data +
Pin 4: Not used
Pin 1: Not used
Pin 2: Not used
Pin 3: Not used
Pin 4: Not used
5
Pin 5: Not used
Pin 5: +5V
Pin 6: Data +
Pin 7: Data -
Pin 8: GND
ArcLine Micro 36