DRYDEN AQUA DA-GEN Manuale d'uso - Pagina 4
Sfoglia online o scarica il pdf Manuale d'uso per Inverter DRYDEN AQUA DA-GEN. DRYDEN AQUA DA-GEN 9.
Anche per DRYDEN AQUA DA-GEN: Manuale d'uso (13 pagine)
Conductivity probe
1
yellow
2
transparent
Cover
1
5
&
Chlorine probe detector
FL2
(rotameter)
3
black
5
brown
6
blue
Flow switch
FL1
2
5
&
pH-Minus deposit
level
4
&
5
TANK
Temperature probe
1
red
2
yellow
3
black
AUX 1
pH
Dosing pump flocculation
pH dosing pump
APF
1
&
2
Heating ON/OFF
Status of the auxiliar relays
Current time
Production intensity
Automatic measurements: pH/redoX/
free chlorine/conductivity
(according to options)
State filtration relay
(see section 5- Filtration)
Manual
man
Automatic
aut
hea
Heating
Smart
smt
Intelligent
int
Boost
bst
Communication display – mother board
red indicates communication error
PLUS key
Modify value/selection
DA-GEN
Dryden Aqua Generator
ISTALLATION MANUAL
1. ELECTRONIC BOX ELECTRICAL CONNECTIONS
1
2
1
2
3
4
5
110-230 V
6
max. 3.15 A
7
1
2
3
4
5
8
1 2 3
AUX 2
Besgo backwash
valve
5
&
6
12:30
1 2 3 4
hydrolysis / electrolysis
00
%
in %
gr/h
Cu/Ag ionization
250
mA
measures
7.2
700
1.00
man
off
MINUS key
OK key
Modify value/selection
Select/confirm
CONNECT ALL THE SENSORS CAREFULLY, A
BAD CONNECTION MAY CAUSE IRREPARABLE
DAMAGE TO THE DEVICE
DRY CONTACT
6
7
8 9
10 11 12 13 14
Free chlorine
4
3
red
black
N
L
A1 A2
14
11
12
FILTER PUMP
LIGHT
Filtration control
Lighting control
9
&
10
7
&
8
2. MAIN SCREEN
Cover
Pol 1
---
Flow
25º
Low
Cover
Pol 1
LOW
Pr on
Pol 1
Pol 1
Pol 2
7.5 OFF
pH
7.0
AL3
7.5
700 OFF
Rx
FL1
AL3
ON/OFF
mV
1.00 FL2
Cl
AL3
ppm
FL1
TANK
7.0
man
off
ON/OFF
FL 1
700
AL3
1.00
FL 1
AL3
TANK
State relay lighting
Manual /
man
aut
UP key
Navigation up
1
1 2 3 4
1
2
3
4
1
1
1
2
2
2
3
3
3
4
4
4
redoX
pH
AUX 3
AUX 4
11
&
Heating control
12
13
&
14
Water temperature
Production automatically reduced to
the % selected
(see display 3.6)
Polarity 1 /
Polarity 2
Pol 2
Waiting time
Filtration stopped due to lack of water flow
Lack of conductivity or salt / low water temperature / scale on
cell / exhausted cell
(check working hours)
Polarity 1 /
Polarity 2
Pol 2
Setpoint pH maximum (if using pH-Minus)
Function of pH dosing pump
Maximum dosing time exceeded
(
Setpoint pH minimum (if using pH-Plus)
Function of chlorine pump
Flow alarm
Setpoint redox minimum
Maximum dosing time exceeded
(
Setpoint Free Chlorine minimum
Flow alarm /
FL 2
Error rotameter Cl
Maximum dosing time exceeded
(
Low level chemical tank
Automatic
DOWN key
Navigation down
Variable speed pump
1
2
slow
medium
3
fast
4
common
Device control SLAVE
1
brown
2
blue
Connection remote display*
Connection WIFI module
1
2
red
yellow
3
green
4
black
*In case of connecting 2
display´s on the device,
remember not to connect
the remote display in this
communication channel. Use
the "Extern" channel instead.
to reset the alarm)
to reset the alarm)
2
to reset the alarm)
RETURN/ESCAPE
key