G.2 Gas (0) - The FL1 alarm is only activated by cell's gas sensor (external flow switch annulled).
G.1
G.2
Siempre ON (1) - The FL1 alarm is never activated (invalidates cell's gas sensor and external flow switch);
Paddle (2) - The FL1 alarm is activated by external flow switch (gas sensor annulled).
Paddle or gas (3) - When both cell's gas sensor and external flow switch are connected, and either of them detects lack of
flow, The FL1 alarm is activated. To connect the external flow switch use the FL1 terminal
Paddle + Gas (4) - When both cell's gas sensor and external flow switch are connected, and both of them detects lack of
flow, The FL1 alarm is activated. To connect the external flow switch use the FL1 terminal
Paddle delay - Delay before FL1 is activated
Relay control through flow detection - Manage the FL1 alarm deactivation in case of lack of flow. Recommended option
for floculant dosification or similar.
H.1
H.2
I.1
I.2
I.2 Node addr: Used for the configuration of more than 2 user interfaces.
For normal operation of the system, keep the value to 1 for this parameter.
K.1
K.2
K.2 Server control and connection port in case there is WIFI Module connected to the system.
For the proper functioning of the system, do not change the default values unless you receive a notice from your provider.
F) DOSING PUMPS
F.3
F.7
F.10 You can associate the level sensor (TANK) to the pH or chlorine (rX). This menu corresponds to the behavior of
the system after the TANK signal activation (acid deposit level TANK).
Ignore – TANK is not shown in the display
Inform – When the sensor detects that the level is low, the TANK alarm is displayed.
Force stop – When the sensor detects that the level is low, the TANK alarm is displayed and the associated dosing
pump stops.
G) EXTRA SETTINGS
H) COUNTERS
H.3
H.2 Reset counters: There are two levels of working hours counters which log the
working hours of the components and devices.
In this service menu the installer can reset the working hour counters on the first
level (for example when a new cell is installed).
The second level of the working hour counters can only be accessed by the factory.
I) CONNECTION
K) WEB IP
12
F.2 There are 2 modes for the pH dosing pump:
F.4
F.3 Normal: Delay - Delay time between detection of incorrect
value and the start of dosing.
F.4 Repetitive: With the two timers you can programm the ON
and OFF time of the dosing pump
Scaling: Proportional reduction of the dosing time (Pump On
time) when getting close to the setpoint. Example 100%: The
pump time is reduced proportionally if the pH is closer than
1 to the setpoint. Example 50%: The pump time is reduced
proportionally if the pH is closer than 0.5 to the setpoint.
F.8
F.6 Other pumps: With the two timers you can programm the
ON and OFF time of the dosing pump
F.8 It corresponds to the behavior of the system after AL3
activation:
Ignore – AL3 is not shown in the display.
Inform – After the selected interval, the AL3 alarm is displayed.
Force stop – After the selected interval, the AL3 alarm is
displayed on the display and the dosing pump stops. To reset
the alarm and the dosing pump, press
.