Dryfast DFV4500 Manuale di istruzioni - Pagina 5

Sfoglia online o scarica il pdf Manuale di istruzioni per Ventilatore Dryfast DFV4500. Dryfast DFV4500 20. Multifunctional fans

EN
Air output
Air pressure max.
Air flow
Connection voltage
Power consumption
Recommended fuse
Mobility
Hose connector
Dimensions L x W x H
Weight
IP class
Noise level max.
If the fan doesn't run, it may have been temporarily disabled by the thermal protection feature.
The fan may start running again automatically. In case of a malfunction, contact your installer.
Is mains power present?
Is the fuse not defective?
Is the wiring tight?
Are the bearings not seized?
Bearings make noise and/or run heavily.
Fan does not start or does not come up to speed.
Motor protection switch turns off fan.
Impeller turns slowly at full mains voltage.
The device vibrates
Use original parts only!
If the unit is still not working properly, contact the dealer where you purchased the fan.
5.300 m³/ h
80 Pa
free blowing
230 V / 50 Hz (1, 1 A
0.23 kW
10 A
portable
1 x ø 450 mm
360 x 480 x 570 mm
12.5 kg
55
max. 53 dB(A) @ 3 m
Replace bearings
4.500 m³/ h
250 Pa
free blowing
230 V / 50 Hz (1.45 A)
0.35 kW
10 A
portable
1 x ø 450 mm
360 x 480 x 570 mm
12.5 kg
55
max. 64 dB(A) @ 3 m
Turn on mains supply.
Switch on controller
Check fuse and replace if defective
Check capacitor and replace if defective
Check motor and replace if defective
Clean the fan
Replace bearings
Check motor and replace if defective
Repair or replace impeller
Check that all phases are present
Check that the correct mains voltage is present
Check the fan set-up surface. Place the device on a solid and
level surface.
Check the screws, especially the space between fan unit and
tube frame.
Tighten the screws if necessary.
Check the fan blades for dirt and clean them, if necessary.
Any imbalance at the fan blades. Contact the dealer where you
purchased the fan.
8.500 m³/ h
80 Pa
free blowing
230 V / 50 Hz (1.8 A)
0.46 kW
10 A
portable
1 x ø 550 mm
360 x 580 x 680 mm
15 kg
55
max.58 dB(A) @ 3 m
5