ANP Lighting Madison Istruzioni per l'installazione - Pagina 2

Sfoglia online o scarica il pdf Istruzioni per l'installazione per Apparecchio di illuminazione ANP Lighting Madison. ANP Lighting Madison 2. Arm/wall mount

IMPORTANT
Cord Mount
Ground Wire
Hanger Bracket (F)
Jam Nut (E)
Nipple (D)
Stem Mount with RTC Plate
Standard 4/0
Junction Box
RTC Box (D)
Screws (E)
Set Screws (C)
Screws (C)
Cast Back Plate
Cover (CBC)
Standard 4/0 Junction Box
(by others)
RLM CORD/STEM MOUNT INSTALLATION INSTRUCTIONS
Safety, Warning and Suggestions
2. Please read instructions carefully before installation.
Standard 4/0 Junction Box
(by others)
3/4" Minimum
Cord Clamp (G)
Approximately 3/4"
Canopy (C)
Bushing (B)
Cord (A)
RTC Cover Plate (B)
Flat, Ceiling Stem
Canopy (B)
Stem (A)
Arm (A)
3. All wiring and installations should meet local, state and national electrical codes.
4. Install correct lamp type and wattage.
1.
Prior to installation, disconnect power
at main electrical box.
2.
Thread nipple (D)/jam nut (E) into strap
as shown, allowing approximately 3/4"
below strap. Tighten jam nut.
3.
Pull cord (A) through bushing (B), canopy
(C), nipple (D)/jam nut (E)/hanger bracket
(F) as shown.
4.
Pull cord thru hanger bracket to adjust
height, position cord clamp (G) with
to tightly crimp the cord clamp.
5.
height.
6.
Cut wires to provide 6" pigtail with junc-
tion box. Jacket can be cut back to 3/4"
from clamp.
7.
Make power and ground wiring connec-
tions.
8.
Slip canopy over nipple and secure with
bushing. Adjust nipple as needed so
1.
Prior to installation, disconnect power
at main electrical box.
2.
Verify that lead wires from shade are long
enough for stem (A) provided.
3.
Feed lead wires through stem and thread
shade onto stem.
4.
If Cast Back Plate Cover (CBC) is
provided, slide over stem (A).
5.
Screw Stem into Flat Ceiling Stem
Canopy (B).
6.
Make wiring connections according to
national and local codes.
7.
Attach Flat Ceiling Stem Canopy with
stem assembly to Junction box with
screws (C) provided.
8.
If provided, place CBC over Flat Ceiling
Stem Canopy (B) and tighten set screw.
1-800-548-3227
ANPlighting.com