3M Dynapro ET 350L3 Manuale di installazione - Pagina 5

Sfoglia online o scarica il pdf Manuale di installazione per Monitor 3M Dynapro ET 350L3. 3M Dynapro ET 350L3 6. Nema 4x hatch
Anche per 3M Dynapro ET 350L3: Manuale di installazione (7 pagine)

3M Dynapro ET 350L3 Manuale di installazione
10. Using a wrench on the body hex, make sure that the
cable fitting still is tightly screwed into the hatch.
11. Insert the hinge pins of the hatch into the hinges of the
ET unit, close the hatch and make sure that the screw
holes in the edges of the hatch line up with the
threaded holes in the unit's enclosure.
Important
If you need to examine cables inside the access hatch, take off
the removable plate (or extended hatch cover) from the hatch.
Closing the hatch
To close the hatch, follow these steps:
1. Attach cables to their respective connectors.
2. Close and fasten the hatch by loosely attaching the
four #6-32 Phillips screws.
3. Using a No. 1 Phillips torque screwdriver, gradually
tighten diagonal pairs until all the screws are equally
tight at a torque of 7 inch-pounds. This may require
about three rounds of tightening.
3M Dynapro ET 350 Monitors (Models 350R and 350L3) and ET 3170 Terminal

Replacing cables

To replace a cable, disassemble the fitting by following
these steps:
1. Using a wrench to hold the body hex stationary,
2. Grip the disconnected cable and pull while turning the
The new cable you install will require a new fitting.
3M Touch Systems Proprietary Information
5
loosen the sealing nut with a second wrench.
cable in a counter-clockwise direction.