DS Produkte 04159 Manuale di istruzioni - Pagina 4
Sfoglia online o scarica il pdf Manuale di istruzioni per Prodotti per la cura della persona DS Produkte 04159. DS Produkte 04159 8.
EN
■
Before initial use you should test the device on your lower arm.
If there is no undesired skin reaction, you can use the device
on your face.
■
When using the device a tingling sensation and a skin redden-
ing is normal and should disappear within half an hour.
■
In order to avoid the formation of blotches, during the ap-
plication the attachment should be kept in constant motion
on the skin. You are recommended to stretch the skin on the
cheeks, for example, to avoid excessive suction.
■
Without pressing against the skin you move the device slowly
along a straight line, and not in circles!
PLEASE NOTE! If the device stops or cannot be switched on, the
battery needs charging.
While the device is running, the suction head is lit blue. The blue
light has an additional purifying function during acne treatment.
Three attachments are supplied:
•
Round pore attachment for cleaning the pores, not suitable
for the skin around the eyes
•
Oval attachment for stimulating the circulation of the skin
•
Microcrystalline attachment for microdermabrasion: removal
of dead skin cells by friction and suction of the face, elbows,
knees etc.
Cleaning Pores
1. Remove make-up and clean your face in the usual way.
2. For optimum results, the pores should be opened before the
application. For this purpose you soak a small, clean fl annel in
hot water, wring it out and place it on your face. As an alterna-
tive you can carefully place your face above a dish with hot
water, or use the device immediately after a shower or bath.
3. Next you pat your face dry.
4. Place the round pore attachment on the suction head.
5. Press the on / off button. The device switches on.
6. In order to remove sebum and blackheads, you place the at-
tachment against the skin (without pressure) and slowly move
it outwards from the centre in straight lines across the skin. Do
not move it backwards and forwards along the same line. Re-
peat if necessary. Any acne spots should be vacuumed briefl y
before the attachment is removed again. Do not move side-
ways!
7. After the application you switch off the device, remove the at-
tachment and clean it.
8. Soak a cotton pad with facial lotion or the like and clean your
face. After that you apply a skin care product.
Microdermabrasion
1. Remove make-up and clean your face in the usual way. Then
dry it thoroughly.
2. Place the microcrystalline attachment on the suction head.
3. Press the on / off button. The device switches on.
4. Begin the facial treatment on the chin and proceed to the
forehead. Move the attachment slowly without pressure over
the skin. Move it outwards from the centre in straight lines.
Do not move it backwards and forwards along the same line.
NOTE: the microcrystalline attachment can be used on parts of
the body such as the elbows or knees.
5. After the application you switch off the device, remove the at-
tachment and clean it.
6. Apply a skin care product.
DS Produkte GmbH, Am Heisterbusch 1, 19258 Gallin, Germany •
*) Calls to German landlines are subject to charges. The cost varies depending on the service provider.
Article number: 04159
Stimulating the circulation of the skin
1. Remove make-up and clean your face in the usual way. Then
dry it thoroughly.
2. Place the oval attachment on the suction head.
3. Press the on / off button. The device switches on.
4. Any areas where wrinkles form (e.g. around the mouth) should
be vacuumed briefl y before the attachment is removed again.
Do not repeat too often in one location – this could lead to
blotches!
5. After the application you switch off the device, remove the at-
tachment and clean it.
6. Apply a skin care product.
Cleaning and Care
NOTE
■
Do not use any corrosive or abrasive cleaning agents!
•
After every use the attachments should be cleaned under run-
ning water. If necessary you can use a mild detergent and cot-
ton buds.
•
Wipe down the device with a damp cloth if necessary and then
dry it with a soft cloth.
•
Store the appliance away from dust and direct sunlight in a dry,
clean place that is not accessible to children and animals.
•
If the attachments do not cling to the suction head, the silicone
ring is probably damaged and must be replaced. Replacement
silicone rings are supplied.
•
If the fi lter in the suction head is dirty, it should be replaced (see
below). Replacement fi lters are supplied.
Changing the fi lter
1. Pull the round silicone insert out of the suction head.
2. Use a sharp object (e.g. needle, tweezers) to remove the dirty
fi lter from the suction head.
3. Separate a fresh fi lter from the foil and place it into the suction
head.
4. Put the round silicone insert back into the suction head.
Technical Data
Article number:
Model number:
Operating time:
Charging time:
Operating voltage:
Charging voltage/current: 5 V DC; 1 A
Power:
Light wavelength:
Disposal
Customer Service / Importer:
All rights reserved.
04159
BZ-0708
approx. 3 – 5 hours (when fully charged)
3 – 5 hours (with 5 V DC; 1 A)
3.7 V DC; (Li-polymer battery, 900 mAh)
max. 5 W
465 nm
Dispose of the packaging in an environmentally
friendly manner and take it to a recycling centre.
Dispose of the device with the integrated battery at
a recycling centre for used electrical and electronic
devices, and not in the household waste. For more
information, contact your local authorities.
✆
+49 38851 314650 *)
Instructions
Z 04159 M DS V1 1017