Contour Gen 2 Flex (Side Bend)
Maximum Loading per 24 VDC Class 2 Power Supply
Power Supply
Rating per module
GEPS24-25U-NA, GEPS24-25-EU (CE only)
Load shall not exceed 0.83A
GEPS24D-60U-GLX, *GELP24-60U-GL
Load shall not exceed 2.5A
GEPS24D-80U
Load shall not exceed 3.3A
GEPS24-100U-GLX, GEPS24D-100U-NA,
USVI-100024FE, USVI-100024FBA
Load shall not exceed 4.0A
GEPS24-100U-GLX2, GEPS24-100U-TT
Load shall not exceed 4.0A
GEPS24-200U-GLX2
Load shall not exceed 4.0A per each (of 2) output channels
GEPS24-300U-GLX2
Load shall not exceed 4.0A per each (of 3) output channels
NOTE: For linear long runs, center connection to the LED strip is recommended to minimize voltage drop.
*GELP24-60U-GL minimum load = 15 ft. (4.57 m).
Maximum Remote Mounting Distance from Driver Ouput
Power Supply
Wattage
25W
60W, 80W, 100W,
180W, 200W, 300W
Dismantling
At the end of life, the contained LED light source may be cut out using suitable wire cutters, removed from the mounting surface,
then replaced per the cutting and installation instructions above, or dismantled and taken to a communal collecting point for
environmentally friendly disposal in accordance with local regulations by a professional installer.
This product is intended solely for the use of non-residential signage lighting and is not intended for use in any other applications.
Electrical products must not be thrown out with domestic waste. They must be taken to a communal collecting point for environmentally friendly
disposal in accordance with local regulations. Contact your local authorities or stockist for advice on recycling. The packaging material is recyclable.
Dispose of the packaging in an environmentally friendly manner and make it available for the recyclable material collection-service.
18 AWG/0.82 mm
16 AWG/1.31 mm
2
Supply Wire
20 ft./6.1 m
20 ft./6.1 m
Conforms to the following standards:
www.gecurrent.com
© 2022 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information provided is subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
SIGN299 (Rev 05/11/22) DOC-2001572
GEXNFS32-1, GEXNFS65-1, GEXNFSRD-1, GEXNFSGL-1,
GEXNFSBL-1, GEXNFSYG-1, GEXNFSRC-1
24VDC, 1.4W/ft. (Strip)
15ft. (4.57 m)
39 ft. (11.88 m)
49ft. (14.93 m)
59ft. (17.98 m)
62ft. (18.89 m)
62ft. (18.89 m) per bank
124 ft. (37.78 m) per PS
62ft. (18.89 m) per bank
186 ft. (56.67 m) per PS
14 AWG/2.08 mm
2
Supply Wire
Supply Wire
25 ft./7.6 m
35 ft./10.6 m
Installation Guide
12 AWG/3.31 mm
2
Supply Wire
40 ft./12.1 m
2