6.2 Changing the battery

To change the battery:
1. switch the control panel to installation mode and ask the master user to press:
master code
2. open the detector casing (see § on Opening),
3. unclip the lithium battery pack,
4. wait 2 min. before replacing the flat lithium battery,
5. close the detector,
6. switch the control panel back to user mode, press:
engineer installer code
• The lithium battery pack must be replaced by the same type of pack with the same technical characteristics,
i.e. (3 V).
• We advise you to use the DAITEM BatLi31 pack available in the catalogue in order to guarantee
individual safety and equipment reliability.
• Dispose of the waste lithium power pack in an appropriate recycling bin.
Waste processing of electrical and electronic devices at the end of their service life (Applicable in European
Union countries and other European countries with a waste collection system). Used on products or product
packaging, this symbol indicates that the product must not be thrown out with household waste. It must be taken
to a waste collection point for electrical and electronic product recycling. When you make sure that this product
is disposed of in the most appropriate manner, you are helping to protect the environment and human health. If you
would like additional information concerning the recycling of this product, please contact your town/city council, nea-
rest waste collection centre or the shop where you bought the product.
then press:
engineer installer code
65
IMPORTANT: the detector's
configuration is saved when the
battery is changed.