DSC HS2LCDPX Manuale di istruzioni per l'installazione - Pagina 3
Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Tastiera DSC HS2LCDPX. DSC HS2LCDPX 11.
control panel for the device. To connect the zone, run one wire
from the device to the 'P/Z' terminal and the other wire from the
device to the B (black) terminal. For powered devices, run the red
wire to the R (positive) terminal and the black wire to the B (neg-
ative) terminal. When using end of line supervision, connect the
zone according to one of the configurations described in the Power-
Series Neo Reference manual.
NOTE: For UL/ULC installations, the zone input is a supervised
type (SEOL/DEOL). The supervision resistor is 5600Ω. If no
EOL supervision is used, there is a three foot maximum distance
required for the connected device. Use only in conjunction with
UL/ULC listed devices.
NOTE: This initiating device connected to this input contact is
not to be used for medical or fire applications.
3. If the 'P/Z' terminal is programmed as an output, a small relay
(such as DSC model RM-1 or RM-2) or buzzer or other DC oper-
ated device may be connected between the positive supply voltage
and the 'P/Z' terminal (max.load is 50mA).
NOTE: For UL/ULC-listed installations, use UL/ULC listed
devices.
Apply Power
Once all wiring is complete, and the equipment is secured to the
building structure with at least two screws, apply power to the
control panel:
1. Connect the battery leads to the battery.
2. Connect the AC transformer.
For more information on control panel power specifications, see
the PowerSeries Neo Reference manual.
Program the Keypad
1. Press [*][8][Installer Code].
2. Use the [<][>] keys to nav-
igate through the menus or jump
directly to a specific section by
entering the section number.
Toggle
Programming consists of tog-
gling on and off options in each
"Toggle name"
section or by populating data
fields. Toggle options are
enabled or disabled by pressing
the corresponding number on the
keypad. For example, to enable
toggle options 1 and 4, press the
[1] and [4] keys. All enabled
options are displayed (see the following diagram).
1. To input data, use the [<][>] keys to select a character then
press the keypad button for the number/letter.
2. Using the [<][>] keys, scroll to the next character and repeat
the procedure. For information on entering HEX data, refer to the
PowerSeries Neo Reference manual.
Language Programming
Enter [000][000]. Enter the two-digit number corresponding to the
language desired:
Table 2: Languages
01 = English
(default)
02 = Spanish
03 = Portuguese
04 = French
05 = Italian
06 = Dutch
07 = Polish
08 = Czech
09 = Finnish
Enroll the Keypad
Keypads can be enrolled automatically or manually. In either case,
the serial number of the device is used as an identifier.
NOTE: If there is no keypad enrolled on the system, once you
power up, the keypad will display the message: Press any key to
enroll. Other keypads can then be enrolled from the first keypad.
Use one of the following enrollment options:
[902][000] Auto Enroll
When this mode is selected, the total number of keypads currently
enrolled is displayed on the keypad.
1. Enter [902][000] to begin the auto-enrollment of new keypads.
As each device is enrolled, the keypad displays the model type,
serial number and slot assignment. Keypads are assigned to the
next available slot.
1
4
[902][001] Manual Enroll
To manually enroll individual keypads:
1. Enter [902][001] or use the [<][>] keys and press [*].
2. When prompted, enter the serial number of the keypad found on
(X)
<>
the back of the device.
3. An error tone is sounded if an invalid serial number is received.
Y/N
Once enrolled, the device model, serial number and slot assign-
ment are displayed. Keypads are enrolled into the next available
slot for the device. The slot assignment can be changed using the
[<][>] keys.
4. To cancel the enrollment of a module, press [#].
NOTE: Once the maximum number of devices have been enrolled,
an error tone sounds and a warning message is displayed.
[902][002] – Module Slot Assignment (LED,
LCD, ICON)
This section is used to change the slot number in which a module
is enrolled. To change the slot number:
1. Enter [902][002] or use the [<][>] keys and press [*].
2. Enter the serial number of the module.
10 = German
20 = Romanian
11 = Swedish
21 = Russian
12 = Norwegian
22 = Bulgarian
13 = Danish
23 = Latvian
14 = Hebrew
24 = Lithuanian
15 = Greek
25 = Ukrainian
16 = Turkish
26 = Slovak
17 = FFU
27 = Serbian
18 = Croatian
28 = Estonian
19 = Hungarian
29 = Slovenian
3. When prompted, enter the new two-digit slot number. The pre-
vious slot assignment is replaced with the new one. An error tone
sounds if an invalid slot number is entered.
[902][003] – Module Slot Assignment (LCD
Only)
Similarly to [002], this section is also used to change the slot num-
ber of a module. With this option, however, the serial number is
not required. To change the slot number:
1. Enter [902][003] or the use the [<][>] keys and press [*].
2. Use the [<][>] keys to locate the module then press [*] to
select.
3. Enter the new two-digit slot number. The previous slot assign-
ment is replaced with the new one. An error tone sounds if an
invalid slot number is entered.
[902][101] Unenroll Keypads
1. Enter [902][101] or use the [<][>] keys and press [*].
2. Use the [<][>] keys to scroll to the specific keypad to delete.
3. Press [*] to select the module and when prompted, press [*]
again to delete it.
[903][101] Confirm Keypad
To confirm the enrollment of individual keypads and to locate them
physically:
1. Enter [903][101] or use the [<][>] and press [*].
2. Use the [<][>] keys to scroll to the applicable keypad. The mod-
ule's serial number and slot number are displayed on the keypad
and the status LEDs on the device flash.
3. To confirm the keypad, press [*]. If communication with a mod-
ule is lost at the time of confirmation, a warning message is dis-
played for 1 second before exiting the section.
Assign a Partition to the Keypad
The keypad must be assigned to a partition if supervision or
keypad zones are required. Keypad assignments and keypad option
programming must be done at each keypad individually.
At each keypad installed on the system:
1. Press [*][8][Installer Code].
2. Enter [861]-[876] for Keypad Programming and Keypad Partition
Mask, corresponding to keypads 1-16.
3. Press [*] for partition assignment.
4. Enter 01 to 08 for partition assignment or use the [<][>] keys to
scroll to the specific partition If partitioning is not used, enter
[01]. For Global keypads, enter [00].
5. Press [#] twice to exit programming.
6. Continue this procedure for each keypad until all have been
assigned to the correct partition.