DSC PC5108 Istruzioni per l'installazione - Pagina 2

Sfoglia online o scarica il pdf Istruzioni per l'installazione per Unità di controllo DSC PC5108. DSC PC5108 2. 8 zone expander

DSC PC5108 Istruzioni per l'installazione
There is a built-in tamper switch on the expander module located in
the top left corner of the circuit board. If the cabinet in which the
PC5108 Zone Expander is mounted has the hardware required to
depress this tamper switch, DO NOT connect anything to the TAM
terminal.
VAUX
VAUX
VAUX
VAUX - Used to provide power for devices. Maximum current draw is not to
VAUX
exceed 100 mA. Connect the positive lead of powered devices to VAUX and the
negative to BLK or any COM terminal.
KEYBUS
KEYBUS
KEYBUS - The 4 wire KEYBUS connection is used by the panel to communicate
KEYBUS
KEYBUS
with the module. Connect the RED, BLK, YEL and GRN terminals to the KEYBUS
terminals on the PC5010, PC5015 & PC5020 main control.
Z1 to Z8
Z1 to Z8
Z1 to Z8
Z1 to Z8 - Wire the zones according to the description found in the control
Z1 to Z8
panel Installation Manual .
Jumper Settings
The PC5108 module can be used to add up to 8 additional hardwired zones to
the PC5010, PC5015, or PC5020 control panel (see Installation Manual for
complete installation instructions).
Jumpers
Jumpers are used to determine which zones will be assigned to the expander.
On control panels with software versions 3.X and higher, the PC5108
v2.0 will operate in a single group of eight zones.
For control panels V3.x and higher, please refer to the jumper settings below...
Expander Zones
Jumpers
Group A (Zones 1-8)
J1
J2
Group B (Not used)
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
System Zones Assigned
J3
ON
Zones Disabled
ON
Zones 9 - 16
ON
Zones 17 - 24
ON
Zones 25 - 32
OFF
Zones 33 - 40
OFF
Zones 41 - 48
OFF
Zones 49 - 56
OFF
Zones 57 - 64
On control panels with software versions 2.X and lower, the PC5108
v2.0 will operate in two groups of four zones.
For control panels V2.x and lower, please refer to the jumper settings below...
Expander Zones
Jumpers
Group A (Zones 1-4)
J1
J2
Group B (Zones 5-8)
J4
J5
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
To Add Hardwired Zones to a Control Panel
1. Connect module to the Keybus (with the panel powered down).
2. Set the jumpers on the module.
3. Power up the system.
4. Enter section [902] and wait 1 minute.
5. Enter section [903] to verify that the module is supervised.
6. Define the zones in sections [002]-[004], [109]-[164] for PC5020.
7. Add the zones to the appropriate partition in sections [202]-[265].
System Zones Assigned
J3
J6
ON
Zones Disabled
ON
Zones Disabled
ON
Zones 9 - 12
ON
Zones 13 - 16
OFF
Zones 17 - 20
OFF
Zones 21 - 24
OFF
Zones 25 - 28
OFF
Zones 29 - 32