DSC Power Series Manuale di istruzioni per l'installazione - Pagina 4
Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Unità di controllo DSC Power Series. DSC Power Series 11. Neo image sensor
Anche per DSC Power Series: Manuale di riferimento (2 pagine), Manuale (18 pagine), Manuale di riferimento rapido (2 pagine), Manuale di installazione (14 pagine), Istruzioni per l'installazione (2 pagine), Manuale rapido (4 pagine)
Program Labels (LCD keypads)
1. Press [*][8][Installer Code].
2. Press [*] and use the [<][>] keys to scroll to Zone Labels and press [*] again.The first zone is dis-
played. Alternatively, enter, [000][001].
3. Use the [<][>] keys to scroll to the zone label to be programmed and press [*] or enter the zone num-
ber (e.g., 001, for zone label 1).
4. Use the [<][>] keys to scroll to the desired character's location, using the [<][>] keys.
5. Enter the number of the corresponding character group until the desired character is displayed (see
the following table). Example, press the "2" key three times to enter the letter "F". Press the "2" key
four times to enter the number "2". Press [*], then scroll to "Save". Press [*] again to save the label.
To delete a character, use the [<][>] keys to move the cursor under the character, then press [0]. If any
key other than [<][>] is pressed before [0], the cursor moves one space to the right and deletes that
character.
[1] - A, B, C, 1 [5] - M, N, O, 5 [9] - Y, Z, 9, 0
[2] - D, E, F, 2 [6] - P, Q, R, 6 [0] - Space
[3] - G, H, I, 3 [7] - S, T, U, 7
[*] - Select
[4] - J, K, L, 4 [8] - V, W, X, 8 [#] - Escape
CHANGE CASE – Will toggle the next letter entries between upper case (A, B, C...) and lower case
letters (a, b, c...).
ASCII ENTRY – Used to enter uncommon characters. Valid entries range from 000 to 255. Use the
[<][>] keys to scroll through the characters or enter a 3-digit number from 000-255. Press [*] to enter
the character into the label.
CLEAR TO END – Clears the display from the character where the cursor was located to the end of
the display.
CLEAR DISPLAY – Clears the entire label.
Continue from Step 2, until all labels are programmed.
Label Library
The Label Library is a database of words commonly used when programming labels. Individual words
can be combined as needed (e.g., Front + Door). Each line of the display supports a maximum of 14
characters. If a word will not fit on a line, scroll right until the cursor appears at the first character of
the second line and then add the word.
To program a custom label using the Label Library:
1. Press [*][8][Installer Code][000][001].
2. Enter [001] (to program the label for zone 01), or use the [<][>] keys to scroll to the Zone Labels
and then press [*]. The current label name is displayed for that zone.
3. Press [*] to open the menu.
4. Press [*] again to select the "Word Entry" option.
5. Enter the 3-digit number corresponding to a word (see Words Library) or use the [<][>] keys to view
words in the library.
6. Press [*] to select the word.
7. To add another word, repeat the previous procedures from step 3.
8. To add a space, press the right scroll key [>].
9. To clear characters, select "Clear to End" or "Clear Display" from the menu.
10. To save the current label and exit, press [#].
Broadcast LCD Labels
If more than one LCD keypad is present on the system, labels programmed on one keypad will be
broadcast to all other LCD keypads, after the change is confirmed.
Change Brightness/Contrast/Buzzer
LCD Keypads
1. Press [*][6][Master Code].
2. Use the [<][>] keys to scroll to either Bright Control, Contrast Control, or Buzzer Control.
3. Press [*] to select one of the following settings:
Brightness/LED Bar Control -15 backlighting levels available.
l
Contrast Control -15 display contrast levels available.
l
Buzzer Control - 15 buzzer control levels available.
l
4. Use the [<][>] keys to scroll to the desired setting.
Keypad Programming
1. Press [*][8][Installer Code].
2. Select one of the programming options identified in the following.
[860] Keypad Slot Number
Not for programming; the two-digit slot number is displayed for informational purposes only.
[861]-[876] Keypad Programming Sections
[000] Address of Partition
Default: 01
A 2-digit entry is required to assign the keypad to a partition. Valid entries are 00-32.
NOTE: LED and ICON keypads must not be assigned as global keypads.
[001]-[005] Keypad Function Key Programming
To program a function key:
Press [*][8][Installer Code].
1. Enter [861]-[876] for keypad programming.
2. Enter [001]-[005] for function keys 1-5 or use the [<][>] keys and press [*].
3. Enter a 2-digit number to assign a function key operation - [00]-[68]. See the following table.
4. Repeat from step 3 until all function keys are programmed.
5. Press [#] twice to exit Installer Programming.
Table 3: Function Key Assignment
Function Key Button Valid Range Default Function
[001]
Key 1
00–68
00–68
[002]
Key 2
[003]
Key 3
00–68
00–68
[004]
Key 4
[005]
Key 5
00–68
Keypad Function Keys
Refer to your system installation manual for a complete list of available function key options.
[00] - Null
[13] - Global Away Arm
[02] - Instant Stay Arm
[14] - Global Disarming
[03] - Stay Arm
[16] - [*][0] Quick Exit
[04] - Away Arm
[17] - Arm Interior
[05] - [*][9] No-Entry Arm
[21] - [*][7][1]Command Output 1 [35] - User Functions
[06] - [*][4] Chime ON/OFF
[22] - [*][7][2]Command Output 2 [37] - Time & Date Program
[07] - [*][6][----][4] System Test [23] - [*][7][3]Command Output 3 [39] - Trouble Display
[09] - Night Arm
[24] - [*][7][4]Command Output 4 [40] - Alarm Memory
[12] - Global Stay Arm
[29] - Bypass Group Recall
Stay Arm
|_____|_____|
03
04
Away Arm
|_____|_____|
Chime ON/OFF
|_____|_____|
06
22
Command Output 2 |_____|_____|
Quick Exit
|_____|_____|
16
[31] - Local PGM Activate
[32] - Bypass Mode
[33] - Bypass Recall
[34] - User Programming
[61]-[68] - Partition Select 1-8