3MillID 3M Mullion Manuale di installazione

Sfoglia online o scarica il pdf Manuale di installazione per Controllori di accesso IP 3MillID 3M Mullion. 3MillID 3M Mullion 2.

SPECIFICATIONS
performance level for access control
This product complies with the following UL294 Access Control Performance
Levels:
Destructive Attack
Level 1
Line Security
Level 1
Endurance
Level 4
Prox
Level 1
Bluetooth
Standby Power
Level 1
See the UL Listed access control unit controller installation instructions for reader
compatibility.
environmental
Operating Temperature
-31°F to + 151°F
(-35°C to +66°C)
Humidity
86 ±3°F
(85 ±5% at 30 ±2°C)
Ingress Protection
IP65
(not evaluated by UL)
Positioning
Suitable for OUTDOOR use.
electrical
Power supply
Power is to be provided by a UL294 Listed,
low-voltage Class 2 power limited supply or
control panel, capable of 4 hours standby.
Voltage
+10Vdc to +16Vdc
Current
Model
Part No.
Idle and Peak current at 12Vdc
Average
3M Inline
3MIL-R11030
15mA
3M Mullion
3MIL-R11330
41mA
3M S-Gang
3MIL-R11320
41mA
3M S-Gang Keypad
3MIL-R11325
62mA
Data Voltage
Rest >4Vdc / Active <1Vdc
Data Output
Wiegand, Clock & Data, Custom Outputs
Indication
1 RGB LED
(+ RGB LED illuminated keypad to 3MIL-R11325)
Sounder
Integral speaker
3millID.com +1 303 475 4972
Specifications subject to change without notice.
©2017 3millID. All rights reserved.
100-02654-C
INSTALLATION GUIDE
dimensions
Model
3M Inline
3M Mullion
3M S-Gang
3M S-Gang Keypad
polymeric materials
Potting compound
Mouldings
wiring
Recommended cable
Cable length
Minimum
recommended wire size
Peak
reader connections
35mA
82mA
82mA
1
100mA
2
3
4
5
6
7
8
9
10
• Supra ® BT LE
Bluetooth is a registered trademark of Bluetooth SIG
Part No.
Size - Inches
( millimetres )
3MIL-R11030
3.8 x 2.1 x 0.8 in ( 96 x 52 x 21 mm )
3MIL-R11330
3.8 x 2.1 x 0.8 in ( 96 x 52 x 21 mm )
3MIL-R11320
4.7 x 3.0 x 0.8 in ( 120 x 76 x 21 mm )
3MIL-R11325
4.7 x 3.0 x 0.8 in ( 120 x 76 x 21 mm )
UL R/C (QMFZ2)
UL746C
Wiring methods shall be in accordance with
the National Electrical Code (ANSI/NFPA70),
local codes, and the authorities having jurisdiction.
BELDEN 953x (or equivalent UL listed) for Wiegand.
BELDEN 9502 (or equivalent UL listed) for RS485.
All cable and wiring must be Listed and suitable for use.
Up to 492 feet (150 m) from controller.
Not less than 24 AWG.
These connections are common to all readers in
the BD series.
-
0V
Supply voltage ground
-
+Vdc
Supply voltage (+10Vdc to +16Vdc)
-
DATA1/CLK
Wiegand or Clock/Data output
-
DATA0/DAT
Wiegand or Clock/Data output
-
GREEN
Green LED control input
-
RED
Red LED control input
-
Buzzer
Buzzer control input
-
TMPR/CP
Tamper or Card Present output
-
RS485-
RS485 Bus
-
RS485+
RS485 Bus
Mounting this reader on (or near) metal may impair
i
the read range of the unit.
3millID - 3M Inline
3MIL-R11030
125kHz
Supra ® BT LE (2.4GHz)
3millID - 3M Mullion
3MIL-R11330
125kHz
13.56MHz
Supra ® BT LE (2.4GHz)
3millID - 3M S-Gang
3MIL-R11320
125kHz
13.56MHz
Supra ® BT LE (2.4GHz)
3millID - 3M S-Gang Keypad
3MIL-R11325
125kHz
13.56MHz
Supra ® BT LE (2.4GHz)
Please turn over for installation guidance notes