ADDAC System ADDAC403 Manuale d'uso - Pagina 5
Sfoglia online o scarica il pdf Manuale d'uso per Unità di controllo ADDAC System ADDAC403. ADDAC System ADDAC403 11. Vc time signature clock sources
ADDAC403 User's Guide
CLOCK SECTIONS
TEMPO (BPM):
BPM can be set with the [BPM] Encoder from 0.1 to 250.0 BPM
BPM can also be set by [TAP TEMPO], push button 4 times to set tempo, likewise for
CV Input.
Button LED will blink at every button push or trigger input.
MENU SETTINGS:
There's 3 Modes for when the Tempo changes to have effect:
INSTANT: Changes have an immediate effect
BEAT: Changes will have effect on the next Beat
BAR: Changes will have effect on the next Bar
MENU SETTINGS:
There's 13 states for dividing/multiplying the incoming Tap /Ping:
SYNC:
Both the push-button and cv input will be synced using two methods:
SOFT: Sets new BPM but does NOT sync to the input clock.
HARD: Sets new BPM and syncs to the input clock.
TIME SIGNATURE:
[BEATS P/BAR] sets how many Beats per BAR: 1 to 16
[BEAT UNIT] sets the unit that represents 1 Beat:
1:whole-note, 2:half-note, 4:quarter-note,
8:eight-note, 16:sixteenth-note, 32:thirty-second note
PAUSE:
[PAUSE] will pause the clock while LED is ON
MENU SETTINGS:
There's 3 Modes for when Pause is disengaged:
HOLD: Resumes Clock where it was paused.
BEAT: Resumes Clock and advances to the next Beat
BAR: Resumes Clock and Resets to the Beat 1
MENU SETTINGS:
There's 2 Modes for how Pause behaves:
GATE: Pauses while Button is pressed or Gate In is On:
TOGL: Toggles Pause State
ADDAC SYSTEM
DIVISION: 1/1 to 1/8
MULTIPLICATION: 1.5 to 4.0