ATSI Handheld Inductive Loop Tester HILT 9000 Manuale d'uso - Pagina 10

Sfoglia online o scarica il pdf Manuale d'uso per Tester di circuito ATSI Handheld Inductive Loop Tester HILT 9000. ATSI Handheld Inductive Loop Tester HILT 9000 17. Handheld inductive loop tester

ATSI Handheld Inductive Loop Tester HILT 9000 Manuale d'uso
HILT 9000 - Inductive Loop Tester

Function Controls Summary

BUTTON
DESCRIPTION
LOOP
Used to measure L, Q, and R
of the loop. Q is measured up
to 15. If Q>15, use Q button to
obtain the actual value of Q
Q
Used to measure high Q
values (when Q is >15)
Used to measure change of
L
inductance
DETECTOR
Used to measure operating
parameters of the loop
system: V
Frequency, and Mode
SET FREQ.
Used to select operating
frequency to measure L and Q
! and "
Used in SET FREQ mode to
increase and decrease
frequency in 1KHz steps.
POWER
Used to turn the unit on and
off.
, Oscillating
P-P
COMMENTS
The loop must be
DC
disconnected from the
system to run this test
The loop must be
disconnected from the
system to run this test
The loop must be
disconnected from the
system to run this test
The loop must be
connected from the
system to run this test
The tester can be
turned off at any time
during or after a test
9