2.08 Programming Audible Alert After Alarm Dialling
After the dialer has dialed, it can be programmed to give an audible or visual indication. Audio
indication is given by the internal buzzer sounding once dialing has been completed and visual
indication is given on the seven segment display
Press: PROG
0
2.09 Programming Dial Cycles
After dialing all programmed numbers, the dialer can repeat the dialing process up to 3 times.
Therefore the total amount of dial cycles may be programmed. The default setting is 2.
Press:
PROG
0
2.10 Programming Alarm Input
There is a option of 2 ways to trigger the dialer either by applying 12Vdc or 0Vdc. The default
setting is 12Vdc. To change the trigger input:
Press:
PROG
0
2.11 Programming Entry Exit Timing
The AD1200 provides the possibility to assign an Entry Exit Timing to the Signal Input. This en-
ables the user directly connect detectors (e.g. motion or smoke detectors) to the signal input. In
this case the AD1200 acts like a small independent alarm panel.
Programming a value of 0 will disable this feature (default).
Programming values from 1 ... 9 correspond to Entry / Exit Times of 10 ... 90 seconds.
Press:
PROG
0
If an Entry Exit time greater than 0 is programmed then the system will act as following:
1.) After the user leaves the User Mode the system will start the Exit Timer. The system indicates
the user with beeps that he should leave the premises. Within this time any signal from the input is
masked. No dial attempt will be initiated.
2.) After the user left the premises the system waits for any signal on the input.
3.) If there is a signal on the input then the system will start the Entry Timer. Again the system
indicates the user with beeps to disarm the system with his User Code. While this time no dial
attempt will be initiated.
4.) If the User enters the User Code correctly the system will be disarmed.
5.) If the User does not manage to enter the User code in time the system will initiate an alarm
condition and start the first dial attempt.