3.2. Strategy 2, "Gradient compensation":
When   the   first   (main)   calibration   is   performed   to   the   primary   listening   position   or   to   the 
center of the listening area, but it is difficult to find the weakest point within the listening area, 
gradient compensation is a good approach. Second phase calibration point for wider area 
correction   can   be  found   by   taking   the   microphone   from   first   calibration   point   toward   the 
closest corner of the listening room by 40­90 cm and down (toward the floor) approximately 
10­20 cm. Wider area calibration second phase will be performed to this achieved position. If 
the first (main) calibration point was in close proximity of walls (distance less than 1m.) , the 
microphone   should   be   moved   only   about   20­40   cm   toward   that   wall   for   second   phase 
calibration. Gradient compensation method usually works well in removing the axial modes 
for larger area in rectangular room.