DSR DSR15 Manuale d'uso - Pagina 7
Sfoglia online o scarica il pdf Manuale d'uso per Caricabatterie DSR DSR15. DSR DSR15 13. Battery charger/maintainer
3. If necessary, press the BATTERY
TYPE button until the correct type is
indicated.
4. Read the voltage on the digital display.
Keep in mind that this reading is only
a battery voltage reading; a false
surface charge may mislead you.
Power-Up Idle Time Limit
If no button is pressed within 10 minutes
after the battery charger is first powered
up, the charger will automatically switch
from tester to charger if a battery is
connected. In that case, the charger will
be set to charge at the maintain mode
and gel cell battery type.
10. CALCULATING CHARGE TIME
BATTERY PERCENT AND CHARGE TIME
This charger adjusts the charging time in
order to charge the battery completely,
efficiently and safely. The microprocessor
automatically performs the necessary
functions. This section includes guidelines
that can be used to estimate charging
times. Use the following table to determine
the time it will take to bring a battery to full
charge. First, identify where your battery
fits into the chart.
BATTERY SIZE/RATING
SMALL
BATTERIES
CARS/TRUCKS
MARINE/DEEP-CYCLE
11. MAINTENANCE INSTRUCTIONS
11.1 Cleaning and user maintenance should not
be done by children without supervision.
11.2 After use and before performing
maintenance, unplug and disconnect the
battery charger (see sections 5, 6 and 7).
11.3 Use a dry cloth to wipe all battery corrosion
and other dirt or oil from the battery clips,
cords and the charger case.
11.4 Ensure that all of the charger components
are in place and in good working condition,
Motorcycle,
6-12 Ah
garden tractor,
12-32 Ah
etc.
200-315 CCA
36-46 Ah
315-550 CCA
46-58 Ah
550-1000 CCA
58-111 Ah
Testing After Charging
After the unit has been changed from
tester to charger (by selecting a charge
rate), it remains a charger. To change the
battery charger back to a tester, press the
CHARGE RATE button until all charge
rate LEDs are off.
Fan
The charger is designed to control its
cooling fan for efficient operation. It is
normal for the fan to start and stop when
maintaining a fully charged battery.
Keep the area near the charger free of
obstructions to allow the fan to operate
efficiently.
CCA = Cold Cranking Amps
Ah = Amp Hour
NR = Not Recommended
Find your battery's rating on the following
chart, and note the charge time given for
each charger setting. The times given are
for batteries with a 50% charge prior to
recharging. Add more time for severely
discharged batteries.
CHARGE RATE / CHARGING TIME
2 AMP
2-3¾ hrs
3¾-10 hrs
11¼-14½ hrs
MO
MO
56 Ah
MO
86 Ah
MO
96 Ah
MO
106 Ah
MO
for example, the plastic boots on the
battery clips.
11.5 Servicing does not require opening the unit,
as there are no user-serviceable parts.
11.6 All other servicing should be performed by
qualified service personnel.
11.7 If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons, in order
to avoid a hazard.
7
•
•
MO = Maintain Only
10 AMP
15 AMP
NR
NR
NR
NR
2¼ -3 hrs
1½ -2 hrs
3-3¾ hrs
2-2½ hrs
3¾-7 hrs
2½-4¾ hrs
3½ hrs
2¼ hrs
5½ hrs
3½ hrs
6 hrs
4 hrs
6¾ hrs
4½ hrs