DSSA Combo 64 Manuale - Pagina 4

Sfoglia online o scarica il pdf Manuale per Attrezzatura di sicurezza DSSA Combo 64. DSSA Combo 64 9.

Name
Input 6
Input 1
Input 5
Input 2
Input 4
Input 3
Input 3
Input 4
Input 2
Input 5
Input 1
Input 6
* Depends on Daytime Running Light Trigger Setting, Input 5 would be operated as Park Light OR Ignition Switch
Battery +
Battery +
Battery -
Output 4 Common
Output 4 NC
Output 4 NO
Output 3
Output 3
Output 2
Output 2
Output 1
Output 1
Description
General Input 1
General Input 2
Door Switch
Park Brake
Park Light /
Ignition Switch*
Head Lights
STB: Switch to Battery Positive
Name
Battery +
Battery +
Battery -
Output 4
Connect to EITHER Battery + OR Battery -
Common
Output 4
NC
Output 4
NO
Output 3
Output 2
Output 1
STB: Switch to Battery Positive

Input Configuration

Default Switch Mode
Momentary STB
Momentary STB
STG
STG
STB
STB
STG: Switch to Ground Negative

Output Configuration

Description
Connect to battery +
Connect to battery +
Connect to battery -
for Output 4
Mobile Phone (optional)
External Alarm
Day Time Running Light
General Output 2
General Output 1
STG: Switch to Ground Negative
Dip Configuration Access
1. Unscrew the four screw holes
2. Remove the cover
3. Change the DIP switch settings
4. Close the cover
5. Screw and secure
Default Active Mode
High
High
Low
Low
High
High
Maximum Fuse
5A
5A
5A
10A
10A
10A
D
S S
A
Digital witching ystems Australia
S
S