DTC Palladium Pd-TX-100 Manuale - Pagina 11

Sfoglia online o scarica il pdf Manuale per Trasmettitore DTC Palladium Pd-TX-100. DTC Palladium Pd-TX-100 20. Palladium series. cofdm transmitter. 100 mw/250 mw output

PROGRAMMING

Transmitter Control Application

Output Frequency (MHz)
(your frequency)
The transmit frequency can be changed by entering the new desired
frequency in this field. Values outside the range supported by a particular
transmitter type will be rounded to the highest or lowest supported
frequency as appropriate. The resolution of the transmit frequency is
complex and resolved to the closest achievable within the constants of the
supported step sizes of 1MHz, 1.6667 MHz and 2.5 MHz.
Modulation Output
OFF
This control is used to turn on and off the RF output. After a configuration
change, the output always reverts to OFF. It must be ON for operation.
Modulation FEC
2/3
The default FEC is 2/3, however improved range operation can be achieved
by selecting FEC 1/3. FEC 1/3 will improve signal range by 3dB. However
FEC 1/3 reduces link capacity to 1.2Mb/s therefore reducing picture
quality.
FEC Link Bitrate Sensitivity 2/3 2.4Mb/s: -99dBm,
1/3 1.2Mb/s: -102dBm
1/16
Modulation Guard Interval
The Guard Interval is fixed at 1/16 in current software releases.
Modulation Bandwidth
2.5 MHz
For the Palladium transmitter products, the modulation bandwidth is fixed
at 2.5MHz.
QPSK
COFDM Mode
The COFDM mode can be changed between QPSK and 16QAM. QPSK is
the default mode and will give the strongest most rugged RF link
Default values are shown in red.
performance. Selecting 16QAM reduces the link performance by 5dB but
improves the link data throughput, giving significantly better video quality.
11