Absolute Process Instruments Cecomp F20B-M8 Manuale di avvio rapido - Pagina 4
Sfoglia online o scarica il pdf Manuale di avvio rapido per Strumenti di misura Absolute Process Instruments Cecomp F20B-M8. Absolute Process Instruments Cecomp F20B-M8 4. Battery powered digital pressure gauges w. memory options & selectable units
Configuration, Calibration, Changing Pass Code
F22BBL Backlight Time Selection
The lower display will indicate BL if the
display backlight is enabled or NO BL if
display backlight is disabled.
Use the s button to enable backlighting
and the t button to disable backlighting.
Press the power button to save the setting.
If NO BL was selected the user setup is
complete and the gauge will restart and be
ready for use with the new configuration.
If BL was selected the current backlight
auto shutoff time is displayed in minutes.
1 minute is the factory default.
Use the s and t buttons to select the
minutes for backlight shutoff time.
A setting of zero disables the auto shutoff timer and the backlight
will be on whenever the gauge is on. The maximum setting is 255
minutes. The gauge auto shutoff time will override the backlight
time. When the desired time is displayed, press and release the
power button to save your selection and restart the gauge.
F20B Memory—M4 Versions
The M4 version allows recording pressure readings of up to four
tires. While in the memory mode the peak reading is captured.
The number 1 is shown on the upper
display. The lower display will indicate the
label for memory 1.
Use the s and t buttons to select MEM 1,
or LF, RF, RR, or LR. The labels can be set
up in any order.
When the desired label for memory 1 is
displayed, press the Power button.
Repeat the steps for the other memory
locations. When the desired label for memory
4 is displayed, press and release the Power
button to save the user configuration and
restart the gauge.
F20B Memory—M8 Versions
The M8 version allows recording of up to eight pressure readings.
While in the memory mode the peak reading is captured.
The eight memory labels can be set for MEM
1 through MEM 8, or for 4 tires and 4 tire
inner liners used for auto racing.
After auto shutoff time selection, the number
1 is on the upper display. The lower display
will indicate the label for memory 1.
Use the s and t buttons to select MEM 1,
or one of the 8 memory labels: LF, LF IN, RF,
RF IN, RR, RR IN, LR, LR IN. The labels can
be set up in any order.
When the desired label for memory 1 is dis-
played, press and release the Power button.
Repeat the steps for the other memory
locations. When the desired label for the last
memory location is displayed, press and release the Power button
to save the user configuration and restart the gauge.
Battery Replacement
A low battery indication will be shown in the upper left-
hand corner of the display when the battery voltage falls
sufficiently. The batteries should be replaced soon after
the indicator comes on or unreliable readings may result.
1. Remove the 6 Phillips screws on the back of the unit.
2. Lift up the battery holder.
3. Remove batteries by lifting up the
positive end of the battery (oppo-
site the spring) taking care not to
bend the battery holder spring.
4. Discard old batteries properly,
do not discard into fire, sources
of extreme heat, or in any haz-
ardous manner.
5. Always replace both batteries at
the same time with high quality
alkaline batteries.
6. Install batteries with correct orientation. Incorrect polarity will
damage the gauge. The negative (flat) end of each battery
should be inserted first facing the battery holder spring.
7. Replace battery holder face down being careful not to pinch the wires.
8. Replace the back cover, including the rubber gasket and rein-
stall the six screws.
C E C OMP
Div. of
Calibration Preparation
Gauges are factory calibrated at approximately 23°C using NIST
traceable calibration equipment. Calibration is not required before
using the gauge. Calibration intervals depend on your quality stan-
BL
dards, but annual re-calibration is customary. Calibration should
No BL
only be performed by qualified individuals using appropriate cali-
Zero/Clear
Memory
bration standards and procedures.
s
t
The calibration system must be able to generate and measure
- or -
pressure/vacuum over the full range of the gauge and should be
at least four times more accurate than the gauge being calibrated.
2
A vacuum pump able to produce a vacuum of 100 microns (0.1 torr
or 100 millitorr) or lower is required for vacuum gauges.
BLTMR
Install fresh batteries and allow the gauge to acclimate to ambient
Zero/Clear
Memory
temperature for 20 minutes.
s
t
Entering Calibration Mode
- or -
With the gauge off, press and hold the t button. Then press the
Power button. Release all buttons when the display indicates
The display begins by indicating the full-scale positive pressure
rating of the gauge in the engineering units as configured by the
factory, and then shows all display.
Before the gauge enters the Calibration Mode, the display ini-
tially indicates _ _ _ _ with the first underscore blinking, and with
CALPC
(calibration pass code) on the lower display.
Enter the 3510 pass code as described in the Configuration Pass
I
Code section.
Calibration Mode
Mem I
The gauge enters and remains in the Calibration Mode until
Zero/Clear
Memory
restarted manually or power is removed. Features not related to
s
t
calibration are disabled and compound range models are set for the
same engineering units for pressure and for vacuum.
- or -
The calibration may be performed in any of the available engineer-
ing units as well as percent (
I
For greatest accuracy, use the s and t buttons to select engi-
LF
neering units for calibration with highest resolution (highest number
of display counts).
Zero/Clear
Memory
s
t
Press and release the Power button when the appropriate engineer-
ing units are displayed. Suggested units are listed below.
Sensor
3 PSI
5 PSI
15 PSI
I
30 PSI
50 PSI
60 PSI
Mem I
100 PSI
Zero/Clear
Memory
200 PSI
s
t
300 PSI
- or -
500 PSI
1000 PSI
I
2000 PSI
3000 PSI
LF IN
5000 PSI
Zero/Clear
Memory
The display will then indicate the currently applied pressure in the
s
t
engineering units selected for calibration.
s and t Button Operation
Each time one of the s or t buttons is pressed and released
quickly, a small change is made to the digitized pressure signal. It
may take more than one of these small changes to result in a single
digit change on the display.
To make larger changes, press and hold the appropriate button.
After about one second, the display will begin to change continu-
ously. Release the button to stop. Then make fine adjustments by
pressing and quickly releasing the buttons as previously described.
Gauge Reference Pressure Gauges
Apply zero pressure by venting the gauge port to atmosphere. The
character display will alternate between
for a display indication of zero using the s and t buttons.
Apply full-scale pressure. The character display will alternate
Lift up the
+SPAN
between
battery holder
full-scale pressure using the s and t buttons.
Apply 50% full-scale pressure. The character display will alternate
+MID
between
50% of full-scale pressure using the s and t buttons.
Gauge Reference Vacuum Gauges
Apply zero pressure by venting the gauge port to atmosphere. The
character display will alternate between
for a display indication of zero using the s and t buttons.
Apply full-scale vacuum. The character display will alternate
+SPAN
between
full-scale vacuum using the s and t buttons.
Apply 50% full-scale vacuum. The character display will alternate
+MID
between
50% of full-scale vacuum using the s and t buttons.
A
A
P
P
BSOLUTE
BSOLUTE
ROCESS
ROCESS
PCT
).
Suggested units for calibration
6.920 FTH2O
5.000 PSI
775.7 MMHG or TORR
61.08 INHG
50.00 PSI
60.00 PSI
7.031 KG/CM2
407.2 INHG
610.8 INHG
3447 KPA
6895 KPA
4613 FTH2O
6920 FTH2O
5000 PSI
ZERO
CAL
and
CAL
and
. Adjust for a display indication of
CAL
and
. Adjust for a display indication equal to
ZERO
CAL
and
CAL
and
. Adjust for a display indication of
CAL
and
. Adjust for a display indication equal to
1220 American Way Libertyville, IL 60048
I
I
NSTRUMENTS
NSTRUMENTS
Absolute Reference Gauges
Apply full vacuum to the gauge. The character display will alternate
ZERO
CAL
between
and
. Press the s and t buttons to obtain
a display indication of zero.
Apply full-scale pressure. The character display will alternate
+SPAN
CAL
between
and
. Press the s and t buttons to obtain
a display indication equal to full-scale pressure.
Apply 50% of full-scale pressure. The lower display will alternate
+MID
CAL
between
and
. Press the s and t buttons to obtain
an indication equal to 50% of full-scale pressure.
Compound and Bipolar Gauges
In addition to the steps described above for pressure gauges, apply
full-scale vacuum. The character display will alternate between
-SPAN
CAL
and
. Adjust for a display indication of actual applied
vacuum using the s and t buttons.
For bipolar and –30.00inHg/+15.00psig compound range models
CAL
.
only, apply 50% full-scale vacuum. The character display will
-MID
CAL
alternate between
and
equal to 50% of full-scale vacuum using the s and t buttons.
Save Calibration
Press and hold the Power button until the display indicates
then release the button to store the calibration parameters in non-
volatile memory and restart the gauge.
Verify the pressure indications at 0%, 25%, 50%, 75% and 100%
of full scale.
Note: it is possible to do a zero calibration without affecting other
calibration points. After Zero calibration, press and hold the Power
button until the display indicates
store the new zero point calibration and restart the gauge.
User-Defined Pass Code Configuration
The factory default pass code 3510 may be changed to a different
value for configuration and/or calibration.
Configuration Pass Code
With the unit off, press and hold the s button to view and/or
change the user configuration pass code. Then press the Power
button. Release all buttons when the display indicates
Calibration Pass Code
With the unit off, press and hold the t button to view and/or
change the user calibration pass code. Then press the Power but-
ton. Release all buttons when the display indicates
Change Pass Code Mode
Before the unit enters the view or change pass code mode, the
display initially indicates _ _ _ _ with the first underscore blinking,
CFGPC
CALPC
and with
or
Note: The unit will automatically revert to normal operation if no
buttons are operated for approximately 15 seconds. To cancel and
return to normal operation, press and release the Power button
without entering any pass code characters.
Enter access code 1220:
Use the s and t buttons to set the left-most digit to 1.
Press and release the Power button to index to the next position.
The 1 will remain, and the second position will be blinking.
Use the s and t buttons to select 2.
Press and release the Power button to index to the next position. 1
2 will remain, and the third position will be blinking.
Use the s and t buttons to select 2.
Press and release the Power button to index to the next position. 1
2 2 will remain, and the fourth position will be blinking.
Use the s and t buttons to select 0.
Press and release the Power button to proceed.
Note: If an incorrect access code was entered, the gauge will return
to the start of the access code entry sequence.
Change Pass Code
Once the access code has been entered correctly, the display will
indicate the existing user-defined pass code with
. Adjust
CALPC
on the character segments.
Press the s or t button to select the first character of the new
pass code.
When the correct first character is being displayed, press and
release the Power button to proceed to the next pass code character.
Repeat above until the entire pass code is complete.
To exit the User Defined Pass Code change mode, press and hold
the Power button.
Release the button when the display indicates
the gauge.
. Adjust
Disposal of Electrical & Electronic Equipment Applicable
in the European Union and other European countries.
This product should not be treated as household waste
when you wish to dispose of it. Please contact your local
waste disposal authority for information and collection
location for recycling electrical and electronic equipment.
You may also return this product via pre-paid shipping
to Absolute Process Instruments or your supplier for proper disposal.
cecomp.com
800-942-0315
F20B, F22B
. Adjust for a display indication
- - - -
- - - -
then release the button to
CFG
.
CAL
.
on the character segments.
CFGPC
or
- - - -
to restart