3onedata IES618 Series Manuale d'uso - Pagina 2

Sfoglia online o scarica il pdf Manuale d'uso per Interruttore 3onedata IES618 Series. 3onedata IES618 Series 4. Managed industrial ethernet switch
Anche per 3onedata IES618 Series: Manuale di installazione rapida (3 pagine)

3onedata IES618 Series Manuale d'uso
1.
Ground screw
2.
Terminal block for relay output
3.
Console port
4.
Terminal block for power input (PWR1, PWR2)
5.
DIP switches
6.
Screw holes for Wall Mounting Kit
7.
DIN-Rail mounting kit
8.
Power input P1 (P2) indicators
9.
System running indicator
10. Relay alarm indicator
11. 100M Base-FX ports (SC/ST/FC)
12. 10/100M Base-T(x) RJ45 ports
13. Fast Ethernet port Link/ACT indicators
【Dimension】
The series of products are the same size, and the type of the
Ethernet interface is different. Unit (mm)
【Power supply input】
The product top panel provides a 4-pin power supply input
terminal block, support DC input. DC power supply input
supports redundancy function, provides PWR1 and PWR2
power input, can use for single, and can connect 2
separately power supply system, use 1 pair terminal block
connect the device at the same time. If one of the power
systems broke, the device can work un-interruptible. Built-in
overcorrect protection, reverse connection protection.
Voltage input range is 12~48VDC. Terminal block defined as:
V1-, V1+, V2-, V2+.
【Relay connection】
Relay access terminals in the top panel of the device.
Between the two terminal relay, as an open circuit state in
the normal nonalarm state, when there is power alarm
information to the closed state. The two terminal block
connector is used to detect a power failure and network
anomaly. The two wires attached to the Fault contacts form
a closed circuit when the device port connection disconnect
or has lost power supply from one of the DC power inputs.
The user can connect the relay to the lamp indicate or
buzzer alarm to remind the relevant staff.
【Console port】
This series product provided 1pcs procedure test port based
on the serial port. It adopts RJ45 interface, located on the
top panel, can configure related command through RJ45 to
DB9 female cable.
【DIP Switch】
The top panel provided 4 bits DIP switch to do function
configure (ON to enable effectively), 1 and 4 are reserved. 2
is for an upgrade. 3 is recovery default factory. Please power
off and power on when you change the status of DIP switch.
- 2 -
【Communication connector】
10/100BaseT(X) Ethernet port
The pinout defines of RJ45 port display as below, connect
by UTP or STP. The connect distance is no more than 100m.
100Mbps is used 120Ω of UTP 5, 10Mbps is used 120Ω of
UTP 3, 4, 5.
RJ45 port support automatic MDI/MDI-X operation. Can
connect the PC, Server, Converter and HUB .Pin 1,2,3,6
Corresponding connections in MDI. 1→3, 2→6, 3→1, 6→2
are used as cross wiring in the MDI-X port of Converter and
HUB. 10Base-T/100Base-TX are used in MDI/MDI-X, the
define of Pin in the table as below.
NO.
MDI signal
1
TX+
1
8
2
TX-
3
RX+
6
RX-
4, 5, 7, 8
Note: "TX±" transmit data± , "RX±" receive data±, "—" not use.
10/100Base-T(X) MDI (straight-through cable)
10/100Base-T(X) MDI-X (Cross over cable)
MDI-X signal
RX+
RX-
TX+
TX-