Wiring the Relay Output
The relay alarm output contacts are
in the middle of the terminal block
connector. By inserting the wires
and setting the DIP switch of
the respective Port Alarm to "ON",
the relay output alarm will detect
any port failures and form a short
circuit. The alarm relay output is
"Normal Open." The alarm relay output closes if there is a port or power failure.
DIP Switch Settings for Alarm Relay Output
Pin
Status
ON
P1 to P8
(Pin 1 – 8)
Off
ON
P9
Off
Connecting to the Network
Connecting the Ethernet Ports
Connect one end of an Ethernet cable into the Ethernet port of the RocketLinx ES8108 or
ES8108F and the other end to the attached device. All Ethernet ports support auto MDI/MDIX
functionality. The yellow LED is lit for a 100Mbps link and remains off for a 10Mbps link. The
green LED is lit for link up and blinks for packet transmit and receive. The fiber port has one
LED, which is lit if the port is operating in full-duplex mode and blinks when the port is
transmitting or receiving data.
Description
To enable port link down alarm at this port.
To disable port link down alarm at this port.
To enable power failure alarm.
To disable power failure alarm.
Maximum 1A current / DC 24V
Alm
PW1
PW2
Alarm Control
port 1~8
3
Alarm
System
Extra Power
System
power