Auber WS-1500ES Manuale di funzionamento e istruzioni - Pagina 2

Sfoglia online o scarica il pdf Manuale di funzionamento e istruzioni per Regolatore di temperatura Auber WS-1500ES. Auber WS-1500ES 18. Precision pid temperature controller

operation. If the sensor is left outside, controller will assume the temperature is
low even if the controlled subject is already very hot. The controller will provide full
power to the heater. It will not only overheat the controller, but also damage your
appliance, and even cause a fire. If the sensor is not permanently mounted on the
system and left it outside of system is a potential problem, you should enable the
open loop alarm function (see page 11 for details).
• This controller is designed to control the devices recommended by Auber
Instruments only. Using it to control a not recommended device can be dangerous
and cause fire. Auber Instruments is not liable for damages caused by misuse of
the controller. If you are not sure the controller can be used, please contact Auber
Instruments before use.
• If an abnormal display or noise is observed, turn the controller off, unplug the
power cord and contact the manufacturer before using it again.
• Clean the controller only when it is cool and unplugged.
• Do not allow children to operate the controller.

Specifications

Input voltage:
Output voltage:
Maximum Current:
Fuse Size:
Control Action:
Control Mode
Output switching device:
Sensor type:
Sensor tip dimensions:
Sensor cable length,
Alarm:
Timer Range:
Temperature display unit:
Temperature resolution:
Temperature display range: -50 to 400 °C or -58 to 752 ° F.
Temperature accuracy:
Dimension:
Weight:
Warranty:
Operating Instructions
100 to 240 VAC 50 /60 Hz.
Same as the input.
15A.
15A Fast blow.
Heating (reversed action) or cooling (direct action).
PID, PI, PD P or On/off.
Built-in optically isolated solid state relay with zero voltage
crossing switching.
Pt100 RTD sensor.
4 mm diameter x 40 mm long.
3 ft (915 mm).
High limit alarm and Open loop alarm with LED and
buzzer.
0.1 to 99.9 hours. It can be turned off by user.
Celsius or Fahrenheit.
1 °C or 1 °F.
1°C (1°F).
6 x 3.2 x 7 inch (155 x80x170 mm) W x H x D.
2.9 lb (1.5 kg).
1 year for controller, 90 days for sensor.