Auber Instruments DSPR-5 Manuale d'uso - Pagina 4
Sfoglia online o scarica il pdf Manuale d'uso per Accessories Auber Instruments DSPR-5. Auber Instruments DSPR-5 6.
Auber Instruments, Inc.
Manual Control Mode
When the SV is set to a percentage value, the controller works in manual control mode, which means
the controller will send the power percentage determined by the user. The lower window will show
letter "P" on the left to indicator the SV is a percentage value. The yellow A‐M indicator should be on.
Auto Control Mode
Figure 3. Compare the differences of the display on a DSPR‐5 in Auto Control Mode with the SV set at 100°F (left) and
the controller in Manual Control Mode with the SV set at 100% output (right).
Please see the two images in Figure 3, which show a controller in Auto Mode on the left, and a
controller in Manual Mode on the right. The controller in Manual Mode has the A‐M indicator turning
on and the letter "P" (P) in the lower window.
To switch between Auto Mode and Manual Mode:
1. Simply turn the knob to change the SV to either a temperature (auto mode) or a percentage
value (manual mode). The SV can be changed continuously from 0% to 100% to 0°F to 932°F.
2. As the SV value transits between percentage value "P 100" and temperature value "0" degree,
the lower window to prompt either "TEMP" (temp) or "PCT" (Pct) briefly to indicate the
new SV will be a temperature value or a percentage value.
3. When the SV is set to a percentage value, the lower window will show letter "P" on the left and
the A‐M indicator will turn on.
4. When the SV is set to a temperature value, the lower window will only show a number and the
A‐M indicator will turn off.
8. Access the Menu
Press down the knob and hold it for 2 seconds to bring up the menu. The top window will show "go to"
(GOTO). Turn the knob to change the lower window to "CTRL" (CTRL) or "SYST" (SYST), then press
down the knob shortly to enter next level of menu. When the controller is in the menu system, if there
is no action for 30 seconds from the user, the controller will automatically return to the normal
operating mode.
Manual Control Mode
Page 4 of 6
www.auberins.com