Sfoglia online o scarica il pdf Manuale d'uso per Controllore Concens C4-MKII. Concens C4-MKII 9. Actuator controller for up to 4 actuators
U S E R M A N U A L
Furthermore, you have a "Program" button for downloading the parameter settings to the controller
once you have finished your adjustments.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
8
|
|
C4-M K I I v6 62
U S E R M A N U A L
"Disconnect" button disconnects the controller from the software.
"Monitor" reveals information about internal communication.
"Live" enables real time current measuring.
"Reset C4" restarts controller and disables real time current measuring.
Embedded bootloader. Used for firmware update.
Maximum total current for all channels running simultaneously.
Adjustment for maximum deviation for motor in the same group.
Values that refer to the voltage level of the battery alarms. These are not thought as adjustable.
Operation delay.
Selectable PWM frequency.
Selectable alarms. As default all alarms are active. When unticked, safety is still maintained but
you will not get any beep- or LED blinking signals.
Select number of the button for normal travel.
Select number of the button for sub-group. Sub-group is used for running all channels
simultaneously. Not the same as a calibration.
Setting of start and stop ramps.
Adjustment of travel speed in either direction.
Adjustment of maximum current or I-trip in either direction. 100 = 1 A
Adjustable stop or limitation of stroke length in either end of the stroke.
Adjustable calibration speed and current.
Choice of group. No group = blank, Group 1 = 1, Group 2 = 2
Enable or disable hall. Blank = actuator with no hall. Ticked = actuator with hall.
Copy parameters to next or previous channel.
|