Concentric 10590 Istruzioni per l'uso e manuale delle parti - Pagina 3

Sfoglia online o scarica il pdf Istruzioni per l'uso e manuale delle parti per Generatore portatile Concentric 10590. Concentric 10590 4. Ac hydraulic power unit for auto hoists

269xxxx
Installation (Continued)
When wiring the motor, follow all local electrical and safe-
ty codes as well as the National Electrical Code (NEC) and
Occupational Safety and Health Act (OSHA).
For Single Phase Motors use 3-wire cords with 3-prong ground-
ing type plugs.
WARNING!
REPLACE OR REPAIR DAMAGED OR WORN POWER CORDS
IMMEDIATELY.
WARNING!
DO NOT OPERATE UNITS WITHOUT PROPER GROUNDING.
CAUTION
DO NOT RUN HYDRAULIC UNIT DRY; SEVERE PUMP DAMAGE
MAY RESULT.
CAUTION
Always shut electrical source off when servicing machinery.
MODEL 10590
PRIOR TO OPERATION:
1. Double check all hydraulic and electric connections.
2. Confirm that reservoir is filled with hydraulic fluid.
3. Put all equipment guards in place.
4. Clear all persons from work area.
5. Check for loose tools, equipment, or anything that might inter-
fere with operation of equipment.
OPERATION
1. START UP - When initially starting unit up, be sure to jog the
unit (intermittently run unit) several times. This will prime the
pump and fill the hydraulic lines.
2. After hydraulic lines have been filled check reservoir for suf-
ficient oil level. Replenish oil level if necessary.
DO NOT OVERFILL.
AUTO HOIST SAFETY GUIDELINES:
A. Remain clear of lift when raising or lowering vehicle.
B. Do not exceed weight capacity of lift.
C. Clear area if vehicle is in danger of falling.
D. Avoid excessive rocking of vehicle when on lift.
E. Lift should be used by trained operator only.
F. Use vehicle manufacturer's lift points.
G. Always use safety stands when removing or installing
heavy components.
H. Keep feet clear of lift while lowering.
I. Allow lift access to authorized personnel only.
J. Read operating and safety manuals before using lift.
K. Proper lift maintenance and inspection are necessary for
safe operation.
L. Do not operate a damaged lift.
1. Keep the reservoir filled with hydraulic fluid. Use a good qual-
ity automatic transmission fluid (ATF). To refill the reservoir
with clean oil, use a clean funnel fitted with a fine mesh wire
screen. Do not use a cloth strainer. Most pump/fluid failures,
valve malfunctions, and short unit life can be traced directly or
indirectly to dirt or other foreign materials (water, chips, lint,
etc.) entering or already in the hydraulic system.
2. Make frequent inspections of hydraulic oil and change if con-
taminated.
3. Regularly inspect hydraulic hoses and fittings for wear or leak-
age.
4. Keep the unit clean of dirt and foreign materials.
5. Keep electrical connections clean.
– 3 –
Operation
CAUTION
CAUTION
CAUTION
Maintenance