3onedata IES318-2F Manuale di installazione rapida - Pagina 2
Sfoglia online o scarica il pdf Manuale di installazione rapida per Router di rete 3onedata IES318-2F. 3onedata IES318-2F 2. Unmanaged industrial ethernet switch
Note:
1.
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
2.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
3.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
Power Supply Connection
DC power supply
The series devices provide 4 bits power
supply input terminal blocks and two
independent DC power supply systems
for PWR1 and PWR2. The power supply
has
nonpolarity
functions, it can normally operate after reverse connection.
Power supply range: 12~48VDC
Note:
1.
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
and then plug the power supply plug contact and power
on.
2.
Power OFF operation: first unpin the power plug, then
remove the terminal block wiring part, please note the
operation order above.
Relay Connection
Relay terminals are a pair of normally open
contacts in device alarm relay. They are open
circuit in normal non alarm state, closed when
any alarm information occurs. E.g. it's closed
when power off, and send out alarm. This series switches
support 1 channel relay alarm information output, support
network abnormal alarm output, it can be connected to
alerting lamp, alarm buzzer, or other switching value
collecting devices for timely warning operating staffs when
alarm information occurs.
DIP Switch Setting
and power on again.
DIP switch define as follow:
1. Flow control
3. Port alarm
Checking LED Indicator
LED
indictor
comprehensively simplify the fault solution. The function of
each LED is described in the table as below:
LED
and
anti-reverse
PWR1
PWR2
ALM
RUN
Link/ACT
Specification
Panel
100Base-FX
Provide 4-bits DIP switch for function setting,
where "ON" is enable valid terminal. Changing
the status of DIP switch doesn't need power off
2. Force 10M (RJ45)
4. Reserved
monitors
the
operating
status
State
Description
ON
PWR1 is connected and running
normally
OFF
PWR1 is disconnected and
running abnormally
ON
PWR2 is connected and running
normally
OFF
PWR2 is disconnected and
running abnormally
ON
Port link alarm
OFF
Port link without alarm
ON/OFF
Device abnormal
Blinking
Device is running well
ON
Port connection is active
Blinking
Data transmitted
OFF
Port connection is not active
100Base-FX, interface SC/ST/FC
optional
100Base-TX
10/100Base-T(X) self-adapting RJ45
port, half/full duplex self-adapting or
compulsive working mode, support
MDI/MDI-X self-adapting
Console port
Reserved
Alarm
2-core 7.62mm pitch terminal block,
interface
support 1 relay alarm output
Indicator
Power indicator, run indicator, interface
indicator, alarm indicator
Exchange attributes
Backplane
1.6G
bandwidth
Packet buffer
1Mbit
to
size
MAC table
2K
size
Power supply
Input power
DC power supply series products 12 ~
supply
48VDC
support redundant double power
supply, nonpolarity
Access
4-core 7.62mm pitch terminal blocks
terminal
Consumption
IES318
No-load consumption: 1.3W@48VDC
Full-load consumption: 3.6W@48VDC
IES318-1F
No-load consumption: 3.2W@48VDC
Full-load consumption: 4.5W@48VDC
IES318-2F
No-load consumption: 4.5W@48VDC
Full-load consumption: 8.5W@48VDC
Working environment
Temperature
Working temperature:-40℃~75℃
Storage temperature: -40℃~85℃
Working
5%~95% (no condensation)
humidity
Protection
IP40 (metal shell)
grade