Abt ABT-60 Manuale di installazione - Pagina 5
Sfoglia online o scarica il pdf Manuale di installazione per Sensori di sicurezza Abt ABT-60. Abt ABT-60 9. Dual-beam active photoelectric intruder detector with digital frequency conversion
1.Remove the cover and connect power.
2.Observe the collimation effect at a distance of 5cm
from the viewfinder.
3.Adjust the vertical adjustment screw and the
horizontal angle adjusting wheel in order that the
image of opposite detector falls into the central part
of the viewing hole. At this time, the GOOD indicator
of receiver shall light up; if not, adjust it repeatedly.
The accuracy of beam alignment turns higher;
the red LEVEL indicator becomes brighter.
Vertical adjustment screw
down
horizontal adjustment bracke
Multimeter selects DC 10V
5cm
up
1. Insert the test pen into the test hole (please
note the +,- polarity)
2. First adjust the horizontal angle until the test
hole voltage output maximize. Then adjust the
vertical angle by the same way till the voltage
reaches the value above that of below diagram.
3. If it can't reach 1.1V or higher voltage, the
transmitter and receiver shall be regulated again.