3onedata IES618-2F-4D(RS-232)-P Manuale d'uso - Pagina 5
Sfoglia online o scarica il pdf Manuale d'uso per Router di rete 3onedata IES618-2F-4D(RS-232)-P. 3onedata IES618-2F-4D(RS-232)-P 6. Ies618-4d series industrial ethernet switch
installation require, including the power needs and abundant
space. Whether it is close to the connection equipment and other
equipments are prepared or not.
1. Avoid in the sunshine, keep away from the heat fountainhead or
the area where in intense EMI.
2. Examine the cables and plugs that installation requirements.
3. Examine whether the cables be seemly or not (less than 100m)
according to reasonable scheme.
4. Screw, nut, tool provide by yourself.
5. Power: redundant 12-48VDC o power input
6. Environment: working temperature -40~75℃
Relative humidity 5%~95%
DIN rail installation
In order to use in industrial environments expediently, IES618-4D
series adopt 35mm DIN-Rail installation, the installation steps as
fellows:
1. Examine the DIN-Rail attachment
2. Examine DIN Rail whether be firm and the position be
suitability or not.
3. Insert the top of the DIN-Rail into the slot just below the stiff
metal spring.
4. The DIN-Rail attachment unit will snap into place as shown
below.
Wiring Requirements
Cable laying need to meet the following requirements,
1. It is needed to check whether the type, quantity and
specification of cable match the requirement before cable
laying;
2. It is needed to check the cable is damaged or not, factory
records and quality assurance booklet before cable laying;
3. The required cable specification, quantity, direction and
laying position need to match construction requirements,
and cable length depends on actual position;
4. All the cable cannot have break-down and terminal in the
middle;
5. Cables should be straight in the hallways and turning;
6. Cable should be straight in the groove, and cannot beyond
the groove in case of holding back the inlet and outlet holes.
Cables should be banded and fixed when they are out of the
groove;
7. User cable should be separated from the power lines.
Cables, power lines and grounding lines cannot be
overlapped and mixed when they are in the same groove
road. When cable is too long, it cannot hold down other
cable, but structure in the middle of alignment rack;
8. Pigtail cannot be tied and swerved as less as possible.
Swerving radius cannot be too small (small swerving causes
terrible loss of link). Its banding should be moderate, not too
tight, and should be separated from other cables;
9. It should have corresponding simple signal at both sides
of the cable for maintaining.
【Specification】
Technology
Standard: IEEE802.3, IEEE802.3u, IEEE 802.3x, IEEE802.1Q,
IEEE802.1p, IEEE802.1D, IEEE802.1W
Protocol: ARP, ICMP, TCP, UDP, DHCP, DNS, HTTP, Telnet,
SW-RingTM
Flow control: IEEE802.3x, back pressure control
Function
Function: SW-RingTM, QOS, 802.1Q VLAN, port-trunking,
static multicast filter, port mirroring, Broadcast storm control,
flow statistics, upgrade online, up and download configuration file,
user name access system.
SW-RingTM: Single, Couple, Chain, Dual homing ring.
Serial device server: 4 port serial device sever, each port
support 4pcs TCP or UDP session connection
Interface
100M Ethernet: 10/100Base-TX self-adapt RJ45 port.
100M fiber port: 100Base-FX (SC/ST/FC)
Console port: Procedure debug (RS-232), RJ45
Alarm port: 2 bit 7.62mm terminal block,
1 channel relay alarm output
Serial
RS-232 signal:TXD,RXD,RTS,CTS,DTR,DSR,GND
RS-422 signal: T+, T-, R+, R-, GND
RS-485 signal: D+, D-, GND
Parity: None,Even,Odd,Space,Mark
Data bit: 5bit,6bit,7bit,8bit
Band rate; 300~115200bps
Direction control: RS485 side adopt ADDC technology,
auto detect and control data transfer direction
Loading: RS-485/422 side support 32 nodes loop back
Protection: 2KV isolation, 15KV static protection.
Connector: RS232: DB9 male, RS485/4225 bit terminal block
Transfer distance
Twisted cable: 100m(CAT5/CAT5e)
Multi mode fiber: 1310nm,2Km
Single mode fiber: 1310nm, 20K, 1310nm, 40Km
1310nm, 60K, 1550nm, 80Km
RS-485/422: 1200m
RS-232: 15m