How to install the actuator
- Make sure the gate wings stops on mechanical end limit fixed on the floor (not
mandatory for FC actuators where mechanical limit stops is provided on board)
- SAFETY System in compliance with EU norms:
EN 12453
ENSURE SAFETY AND PREVENT ENTRAPMENT- CRUSHING
Any gate or garage door opener is required by the European Union to attent a series
of strict and restrictive mandatory regulations which clearly regulate the automation
industry.
Any new or existing installation requires a declaration of conformity issued by the
manufacturer.
DUCATI not only self-certify his products, but also mandated International Notify
body laboratories to perform full tests to certificate the compliance of the products to
all applicables EN norms.
DUCATI ensure that the forces generated by a correctly installed gate opener, when
touching a person or an obstacle are limited and that they do not exceed the values
specified in Annex A of BS EN 12453:2001.
The final machine to be tested is composed by 2 foundamental elements: the
structure ( gate or garage door) and the automation device. This 2 elements
compose the machine: automated electric gate/ automated electric gate system.
Any new or existing installation requires a declaration of conformity issued by the
final installer. The installer must test the final machine and attest the compliance
to the latest European standards concerning impact forces in case of obstacle
detection. Tests must be performed with a dinamoteter in precisely specified
positions
Ensure safety and prevent injuries:
- Place warning sign of automated gate on the gate or nextto it. Permanently fix a
label warning against entrapment in a prominent place or just near any fixed control
- Without a properly working safety system, people (particularly small children) can
be SERIOUSLY INJURED or KILLED by a closing door. After installation ensure that
the mechanism is properly adjusted.
- Never permit anyone to cross the path of a closing gate.
- No one should go close to a stopped, partially open gate.
- Never leave children unsupervised near a gate opener, whether moving, open,
closed or stopped.
- Never permit children to play with the gate opener's remote control buttons or
transmitters, and do not allow children to use them to operate the gate opener.
Always keep remote controls out of reach of children.
- Install wall-mounted gate controls out of the reach of children and away from
moving parts of the gate.
- Always keep the gate in sight until completely closed.
28
- While the gate is closing, do not attempt to stop it by hand. This is extremely
dangerous.
MOUNTING HARDWARE:
To compleete the installation you need at least following material:
plastic hammer;
pinching for Seeger;
level;
frame fixing;
Cross screwdriver PH2;
flat screwdriver 2,5 mm;
adjustable wrench;
outdoor electric cable ( 2 poles) H07NRF length according to the connection of the
two actuators to the control box;
4 bolts for fixing plates with the gate with a diameter 8 mm length according to the
thickness of the-gate;
4 bolts for fixing plates with the pillar with a diameter 8 mm length according to the
thickness of the pillar; pinching;
vice;
cable clamp.
Outdoor electric cables for additional accessories connections (0,5mmq)
Prepare all the tools and material of use necessary to the installation.
Tools must be in perfect state and in conformity with the safety rules indicated by
the national law.
Prepare and install an insulated underground ICT25 mm shealth to pass the
actuator cable (2x1 mmq) to the contol box as well as the photocells cables.
How to install the actuators
3. General installation diagram
The diagram on page 8 shows an example of a typical automatic system.
Referring to this diagram, determine the approximate location where you will install
each component envisaged in the system and the most appropriate connection
diagram.
The actuators should preferably be installed at a height between the two gate hinges,
and always in line with a reinforced horizontal cross of the gate to fix them in a
structurally strong point. In case the gate is not provided wit a reinforces horizontal
cross, the gate structure must be reinforced at the actuator fixing point
The actuator should anyway never beeing installed less than 15 cm from the ground