Anyload EC100 Manuale operativo - Pagina 8

Sfoglia online o scarica il pdf Manuale operativo per Bilance Anyload EC100. Anyload EC100 12. Counting scale
Anche per Anyload EC100: Manuale operativo (6 pagine)

Unit weight transfer
1.
2. Press M1 to M9 to transfer the unit weight from memory.
Total weight clear
1. Press [TOTAL] to show total pieces on the third line of the
2. Press [MC] to show the unit which will be cleared.
3. Press [CE] to confirm clear.

7. CALIBRATION

7.1 When to calibrate?

Calibration may be required when it is initially installed or if the
scale is installed to an environment where gravitational pull is different
from where the scale is initially calibrated. Also, recalibration maybe
required considering on the time and length of usage of scale (mechanical
deviations may occurring).

7.2 Linearity calibration:

1. Turn on the scale, check if it is responding stable and then turn it off.
2. Press and hold [TARE] key and then switch on the scale. The display
will show LINE on first line, CAL-0 (flashing) on the second line and AD
value on the third line.
3. Linearity calibration will require more than one test weights depending
on the capacity of the scale. The table below shows the required test
weights of each model:
Models
EC100-1.5kg
EC100-3kg
EC100-7.5kg
EC100-15kg
EC100-30kg
EC100-50kg
4. In this instruction, we assume the scale is a 3kg scale.
5. When the AD value is stable, press [ZERO] to start ZERO calibration.
After 2 or 3 seconds, the second line will show 1.0000 because this is
a 3kg scale. If the scale is let us say 15kg capacity then the 1
7 |
ANYLOAD EC100 Counting Scale Operations Manual (V1611)
Press [CE] to clear the memory, the second line of the display
will show 0.
display.
st
1
Test Weight
500g
1kg
2.5kg
5kg
10kg
15kg
nd
2
Test Weight
1kg
2kg
5kg
10kg
20kg
30kg
rd
3
Test Weight
1.5kg
3kg
7.5kg
15kg
30kg
50kg
st
test