Anyload ES310 Manuale d'uso - Pagina 12

Sfoglia online o scarica il pdf Manuale d'uso per Bilance Anyload ES310. Anyload ES310 12. Postal & shipping scale

Anyload ES310 Manuale d'uso
10.

Troubleshooting

Cause
No display
Low-voltage
indication
Error in weighing
data-reading
False calibration
11.

Specifications

Model
Capacity x Readability
Pounds (lb)
Parts counting
Repeatability (std.dev)
Linearity
T range
Over range capacity
Stabilization time
Sensitivity drift (%)
Operation
temperature
Power requirements
Platform size (mm)
Dimensions
Net weight (kg)
Shipping weight (kg)
ANYLOAD ES310 Postal & Shipping Scale User's Manual (V1611)
11 |
Reason
The power plug is not
inserted in the right
place.
The batteries are
expired.
The batteries power is
low.
The scale didn't back to
zero before using.
The scale is not
calibrated.
The calibration weight is
not precise.
To capacity by subtraction
110 or 220V 50/60Hz AC adapter (included); Or 4
400×350×48 (W×L×H) (mm)
Solution
Insert the plug in right
place.
Use the new batteries.
Use the new batteries.
Do not put objects on the
platform, press
button, and then begin to
weight.
Re-calibrate.
Use the precise calibration
weight.
ES310
0.05 kg
330×0.1 lb
Standard
0.05 kg
±0.05 kg
Capacity + 9d
2 sec
0.01
10~40 C
AAA batteries
400×350
4.2
5.2