Anyload DD-KC1 Manuale di istruzioni - Pagina 4
Sfoglia online o scarica il pdf Manuale di istruzioni per Strumenti di misura Anyload DD-KC1. Anyload DD-KC1 11. Digital weight indicator
Anche per Anyload DD-KC1: Manuale operativo (13 pagine)
4. After entering the display menu, Press
parameters; Press
menu;
5. After all the parameters are set, go to "-End-" in the menu, short press
button to save and exit to weighing or counting mode
Menu
Meaning of Menu
Decimal Point Setting
1.dP
Capacity setting
2.CAP
Division setting
3.InC
-End-
Save and Exit
4.3 Weighing
When power-on, with nothing on the platform, press
instrument will then display " 0 ". Place an object on the platform. After the "kg", "lb"
or "pcs" character stops flashing, which means that the data is stable, you can
begin to read it.
4.4 Calibration Methods
4.4.1 Random Single-point Calibration
a) At weighing mode, press and hold
displays"------";
b) Press
c) Press
d) After entering the calibration mode, the window will display"Load"and"0.0kg"
alternately , which means that the weight"0.0kg"should be loaded on the
platform;
e) After making sure that there is nothing on the platform, press
confirm so that the scale begins"0.0kg"calibration.
"0.0kg"calibration, "0.0kg" will flicker rapidly on the display window;keep the
platform calm, stable, and without other interference factors which will influence
Page 4 of 11
button to verify the parameters and return to the
or
button to enter calibration mode;
button to make sure enter the calibration mode;
or
Selective Parameter
0/0.0/0.00/0.000/0.0000
3000,6000,7500,8000,10000,12000,
15000,20000,30000,50000,60000
75000,80000,100000,120000,150000
,200000,300000
d=1/2/5
button until the window
Anyload-manual-indicator-DD-KC1-en-101
key to select
button once, the
button to
In the process of