CONFIGURING THE REMOTE ALARM
The Single Station Remote Alarm can be configured to allow connection to either Normally Open (N.O.) or
Normally Closed (N.C.) pressure switches.
Setting the Alarm for Normally Open or Normally Closed Pressure Switches
The Single Station Remote Alarm is factory set to operate with Normally Closed (N.C.) pressure switches. To
configure the alarm to operate with Normally Open (N.O.) pressure switches perform the following steps:
1. Unplug the power plug from the Remote Alarm power jack.
2. It is best to set the unit on a flat surface face down. Remove the four (4) screws that hold the back cover
on and set the cover aside.
3. Locate the 4 position DIP switch array and then using a stylus or small screwdriver open and close the
DIP switches according to Table 9A, 9B and Figure 9.
5. Place the back cover back onto the base and tighten the screws.
6. Reconnect the power plug into the power jack and plug the unit in.
Figure 9
Table 9A
Settings for Normally Open (N.O.) Operation
DIP Switch
1
2
3
4
5
6
7
8
*OFF = Open, ON = Closed
Table 9B
Settings for Normally Closed (N.C.) Operation
DIP Switch
1
2
3
4
5
6
7
8
*OFF = Open, ON = Closed
-8-
Factory Default Settings
Open
Close
Close
Close
Open
Close
Close
Close
Factory Default Settings
Close
Open
Open
Open
Close
Open
Open
Open