Duct-O-Wire CAS-1RA-O Addendum - Pagina 6

Sfoglia online o scarica il pdf Addendum per Apparecchiature di illuminazione Duct-O-Wire CAS-1RA-O. Duct-O-Wire CAS-1RA-O 7. Collision avoidance and reflector array kit

CAS-2L100 Laser Collision Avoidance Kit Installation and Instructions
SENSOR PROGRAMMING – ENABLE SET POINT 2
NOTE: ALL BUTTON PRESSES MUST BE DONE WITHIN 15 SECONDS
1. Press and release the Mode/Enter button until OU2 is displayed. (3 presses)
2. Press and hold SET button until Hno is displayed, then release.
3. Press and release the Mode/Enter button to confirm.
4. Wait 15 to 20 seconds and the unit will return to the "run" mode.
SENSOR PROGRAMMING – SET POINT 2 (second event distance)
NOTE: ALL BUTTON PRESSES MUST BE DONE WITHIN 15 SECONDS
1. Press and release the Mode/Enter button until SP 2 is displayed. (4 presses)
2. Press and hold the SET button until the desired distance for the second event is
displayed, then release.
3. NOTE: Minimum distance is 1 meter (3.28 feet).
4. Press and release the Mode/Enter button once to confirm. The display will show SP 2.
5. Wait 15 to 20 seconds and the unit will return to the "run" mode.
YOUR LASER COLLISION AVOIDANCE SYSTEM SHOULD NOW BE READY TO OPERATE.
PLEASE ENSURE THAT THE LED's ON THE CONTROL UNIT LIGHT WHEN CRANE IS MOVED TO
EACH SET POSITION.
FACTORY RESET – ONLY IF REQUIRED
1. In the event that improper selections were made during the previous sensor programming
steps, it may be necessary to reset the unit to factory settings. Perform the following
steps ONLY if required or the sensor is not responding as intended.
2. Press and release the Mode/Enter button until EF is displayed. (multiple presses
required)
3. Press and release the SET button once.
4. Press and release the Mode/Enter button until rES is displayed.
5. Press and hold Set button until ---- (4 dashes) is displayed.
6. Confirm by pressing the Mode/Enter button once.
7. After performing the factory reset you must repeat the SENSOR PROGRAMMING steps
outlined in the steps above.