Anywire ASLINK BL296PB-04F-4A-20 Manuale del prodotto - Pagina 14

Sfoglia online o scarica il pdf Manuale del prodotto per Terminali a sfioramento Anywire ASLINK BL296PB-04F-4A-20. Anywire ASLINK BL296PB-04F-4A-20 15.

[Specifications]
■General speci cations
Operating ambient temperature
Operating ambient humidity
Storing temperature
Atmosphere
Operating altitude *
1
Pollution level *
2
*
1 Do not use or store AnyWireASLINK devices in an environment where the pressure exceeds
the atmospheric pressure at an altitude of 0 meters. Doing so may result in malfunction.
*
2 "Pollution level" is an index that indicates the degree of occurrence of conductive substances
in the environment where the device is used.
Pollution level 2 means the occurrence of only pollution by non-conductive substances.
In such an environment, however, electrical conduction could occur due to accidental
condensation.
■Transmission speci cations
Service power supply voltage
Transmission method
Synchronization method
Transmission procedure
Connection mode
Number of
connection points *
3
Number of connection units
RAS function
*
3 The number differs depending on the master unit. Be sure to refer to the manual of the
master unit for the number.
[Outside Dimensions]
■These dimensions are common to all models.
■The gures are examples of output terminal.
0 – +55°C
10 – 90%RH No condensation
-25 – +75°C
No corrosive gas
0 – 2000m
2 or less
24V DC +15% to -10% (21.6 to 27.6V DC)
with a ripple of 0.5Vp-p or less
DC power supply superimposed
total frame/cyclic method
Frame/bit synchronization method
Dedicated protocol
Bus type (Multi-drop method, T-branch
method, Tree branch method)
Number of bit points:
512 points max.
(Input: 256 bits, Output: 256 bits)
Number of word points:
1024 words max.
(Input: 512 words, Output: 512 words)
Up to 128 units
Detection of transmission line disconnection,
transmission line short-circuit, transmission
power supply drop, and
duplicated/unregistered ID
Signal indication and
setting port
Transmission cable
UL style 20276
4-wire × AWG23 (gray) φ4.6
(200)
-BL296*B04F*4A20 14/15-
■Individual speci cations
Number of
occupied
points
Response time *
Detection
function
Current
consumption
Weight
*
4 Indicates the internal processing time of this unit. The maximum transmission delay time
is de ned as "this time + bit transmission cycle time × 2."
*
5 Current consumption for input is a value assumed when all IN-0V pins (NPN) or 24V-IN
pins (PNP) are short-circuited. To connect a 3-wire type sensor, add a total current
consumption of the sensor.
Current consumption for output is a value assumed when all points are turned ON. Add a
total current consumption of load being connected.
80.8
LINK
ALM
OUT0
OUT1
OUT2
OUT3
4.7
0 1 2 3
OUT
BL296SB-04F-4A-20
NPN bit input: 4 points
BL296XB-04F-4A-20
NPN bit input: 2 points/
BL296PB-04F-4A-20
NPN bit output: 4 points
BL296SB-04FS-4A-20
PNP bit input: 4 points
BL296XB-04FS-4A-20
PNP bit input: 2 points/
BL296PB-04FS-4A-20
PNP bit output: 4 points
4
1ms max.
Slave unit voltage drop (DP-DN voltage drop)
I/O power supply drop (24V-0V voltage drop)
Transmission
BL296SB-04F-4A-20
BL296XB-04F-4A-20
BL296PB-04F-4A-20
BL296SB-04FS-4A-20
BL296XB-04FS-4A-20
BL296PB-04FS-4A-20
40g
2-φ3.5
24V
NC
OUT
0V
e-CON compliant 4P socket
ADDRESS No.
bit output: 2 points
bit output: 2 points
I/O side *
5
side
(24V-0V)
(DP-DN)
5mA
22mA
5mA
18mA
5mA
8mA
5mA
22mA
5mA
18mA
5mA
8mA
Unit: mm