Parameter setting
■Changing the threshold setting
This parameter speci es a threshold of light receiving level for
judgment of detection status.
*
The difference in detection status registered by teaching is de ned as 100%.
- Address Writer (ARW-04): Parameter 01
AD value
0-100%
0-4095
0-100%
■Changing the hysteresis setting
This parameter speci es a change in light receiving quantity required to turn
the detection status from ON to OFF.
- Address Writer (ARW-04): Parameter 02
AD value
0-100%
0-4095
0-100%
■Alarm Hi setting
This parameter speci es an upper limit value for alarm judgment.
*
Make sure that Alarm Hi setting is larger than Alarm Lo setting.
- Address Writer (ARW-04): Parameter 03
AD value
0-100%
0-4095
0-100%
*
The setting range depends on the setting of parameter 8.
■Alarm Lo setting
This parameter speci es a lower limit value for alarm judgment.
*
Make sure that Alarm Hi setting is larger than Alarm Lo setting.
- Address Writer (ARW-04): Parameter 04
AD value
0-100%
0-4095
0-100%
■Alarm monitoring time setting
This parameter speci es a monitoring time for alarm judgment.
- Address Writer (ARW-04): Parameter 05
Variable
Unit
3-255
100ms
■Light ON / Dark ON setting
This parameter speci es the Light ON or Dark ON mode.
- Address Writer (ARW-04): Parameter 06
Variable
Description
Through-beam type, Dark (interrupt) ON
0
Through-beam type, Light (transmit) ON
1
Re ection type, Dark (no re ection) ON
2
Re ection type, Light (re ection) ON
3
■Operation mode change enable/disable setting
This parameter speci es whether the diagnosis function is enabled or disabled.
- Address Writer (ARW-04): Parameter 07
Variable
Description
0
Disabled (Simpli ed mode)
1
Enabled (Normal mode)
Factory setting: 50 (AD value)
Factory setting: 5 (AD value)
Factory setting: 0 (AD value)
Factory setting: 0 (AD value)
Factory setting: 50
Factory setting: 0
Factory setting: 0
■Light receiving level indication setting
This parameter speci es the light receiving level indication mode.
Sensing levels of parameter 01, 02, 03 and 04 are automatically converted into
AD value or 0-100%, depending on the setting of this parameter.
- Address Writer (ARW-04): Parameter 08
Variable
0
AD value indication (0-4095 Digit)
1
0-100% indication
[7-segment display]
Fiber side
Transmission side
*
Once a set value is changed by rewriting from the host, the values of
parameters 01, 02, 03 and 04 will not be automatically converted.
■Light emitting power setting
This parameter speci es a light emitting level.
- Address Writer (ARW-04): Parameter 09
Variable
0
1
2
■ON Delay setting
This parameter speci es an ON delay time.
- Address Writer (ARW-04): Parameter 10
Variable
0-999
■OFF Delay setting
This parameter speci es an OFF delay time.
- Address Writer (ARW-04): Parameter 11
Variable
0-999
■One Shot setting
This parameter speci es a one-shot time.
- Address Writer (ARW-04): Parameter 12
Variable
0-999
-L*F1011 8/11-
Description
Factory setting: 0
ON/OFF threshold display (green)
In the case of "Parameter 8 Variable 0: AD value indication"
A threshold setting is indicated in the range of 0 to 4095.
In the case of "Parameter 8 Variable 1: 0-100% indication"
A threshold setting is indicated in the range of 0 to 100%.
(0% and 100% are the minimum and maximum AD values
registered by teaching, respectively.)
Light receiving level display (red)
In the case of "Parameter 8 Variable 0: AD value indication"
An AD-converted light receiving level is indicated in the
range of 0 to 4095.
In the case of "Parameter 8 Variable 1: 0-100% indication"
A light receiving level is indicated in the range of 0 to 100%.
(0% and 100% are the minimum and maximum AD values
registered by teaching, respectively.)
Description
High
Middle
Factory setting: 0
Low
Description
Factory setting: 0
100ms
Description
Factory setting: 0
100ms
Description
Factory setting: 0
100ms