Duevi EZY-LAN HW 4A Manuale dell'installatore - Pagina 10

Sfoglia online o scarica il pdf Manuale dell'installatore per Sistema di sicurezza Duevi EZY-LAN HW 4A. Duevi EZY-LAN HW 4A 13. Wireless alarm panel with ethernet + wi-fi + gsm + lte

Alarm zones: up to 4 zones which, following
an alarm, generate the image capture
12.8 Scenarios (SETUP)
A Scenario is a list of Actions (maximum 16) that
the control panel carries out in sequence with a
single command.
The SCENARIOS page contains the list of all
created scenarios. Pressing the icon
expands the view of the Actions contained in the
Scenario.
Pressing the icon
scenario.
Pressing the icon
settings, where you can change its properties.
Scenario name: is the name with which the
scenario
is
identified
notifications, events, etc
Action list to execute: this is the sequence of
operations that the control panel performs
each time the scenario is started and may
contain:
-
already defined actions
-
new actions
-
waiting times (in seconds)
Pressing the icon
operation line. It is possible to change the order
of the operation by pressing the double line icon
and dragging the line to the new position.
A Scenario can be started by:
Button of a keyfob
User through the App
Timer Program
Logic
NOTE:
In the settings of each user, it can be
defined a limitation to the scenarios that
he can execute (Allowed scenarios).
12.9 Logics (SETUP)
A logic is a rule that creates a cause-effect link
between a certain event and an operation (Action
or Scenario) that the control panel must perform
every time that event occurs.
The LOGICS page contains the list of all created
logics.
Pressing the icon
Pressing the icon
settings, where you can change its properties.
Logic name: is the name with which the logic
is identified in all menus, notifications, events,
etc
(trash can) deletes the
(gear) you enter the scenario
in
all
(trash can) deletes the
(trash can) deletes the logic.
(gear) you enter the logic
Triggering event: represents the event that
triggers
operations.
available for this event:
-
(info)
-
menus,
-
Operation to execute (at the beginning of the
event): represents what the control panel will
perform each time the triggering event starts.
This operation can be an Action or a Scenario.
Other operation to execute (at the end of the
event): it represents what the control panel will
perform each time the triggering event ends.
This operation can be an Action or a Scenario.
12.10 Monitoring Stations (SETUP)
The control panel can send events to a Monitoring
Station with Contact-ID SIA-DC09 receiver, via
internet connection (on local network or LTE
network).
The MONITORING STATIONS page contains the
list of all created Monitoring stations.
Pressing the icon
station.
Pressing the icon
settings, where you can change its properties.
Sending events to the Monitoring Station:
Activate / Deactivate
Monitoring Station name: is the name with
which the Station is identified in all menus,
notifications, events, etc
Supervision interval: time interval in hours
after which the control panel sends the Life
Test to the station
Associated sectors: represents the sectors for
which events are sent
Prefix: prefix of the account code (ONLY IF
NECESSARY) - provided by the Monitoring
Station
the
execution
The
following
Sector event:
Alarm L1 in sectors (OR logic)
Alarm L2 in sectors (OR logic)
Sectors disarmed (AND logic)
Sectors armed (AND logic)
Sectors armed (OR logic)
Entry delay
Exit delay
Chime
24H alarm
Silent alarm
Zone event:
Zone detection (only zones set in mode
"Only use for logic")
Panel event:
Panic Alarm
Manumission alarm
(trash can) deletes the
(gear) you enter the station
of
the
defined
settings
are