OUTPUTS MANAGEMENT
Shelly devices make the management of outputs
available in the control panel.
The outputs, like the zones, can be set within the
device in which they are present and allow the
following settings:
Output name
Output type: ON / OFF, Impulsive
Status at rest: NC, NO
[IF IMPULSIVE] Pulse duration in seconds
Output category:
-
Light
-
Roller shutter
-
Gate
-
Irrigation
-
Relay
The category is used to assign an icon to the
output and group the outputs by type in the App
control.
PLEASE NOTE
The outputs that are manually controlled
by users must be added, like the zones,
within the sectors. In this way, users will
be able to control only the outputs present
within the sectors to which they have
access.
12.2 Sectors (SETUP)
The use of multiple SECTORS (up to a maximum
of 8) allows you to partition the system, as well as
limit user control to only certain portions of the
system.
Each sector has settings independent from the
others (eg entry time, exit time, alarm times, open
door management, etc).
The SECTORS page contains the list of all
created sectors (two sectors are already present
by default: "Perimetrali" and "Volumetrici").
Pressing the icon
the zones and outputs inserted within the sector.
Pressing the icon
Sector.
Pressing the icon
settings, where you can change its properties.
Sector Name: is the name with which the
sector is identified in all menus, notifications,
events, etc.
Entry Delay: it is the entry delay that is
activated for the zones set as delayed
Exit Delay: it is the exit delay that is activated
at the time of arming (in the case of
simultaneous arming of several sectors, the
longest time is considered)
(info) expands the display of
(trash can) deletes the
(gear) you enter the sector
Low Alarm (L1) duration: duration of the low
level alarm
High Alarm (L2) duration: duration of the high
level alarm
Alert: enable / disable the bell sound (chime)
for the sector
Automation 2xL1=L2: enables / disables the
function whereby when two zones of level L1
detect, an alarm of level L2 is automatically
generated
Open door control: disabled, only notify, zone
inhibition, immediate alarm
Adding or deleting the Zones and Outputs
present within the sector
12.3 Actions (SETUP)
ACTIONS
define
performed manually by the user or recalled within
other programming settings.
An Action can be performed by:
Button of a keyfob
User through the App
Scenario
Timer Program
Logic
The ACTIONS page contains the list of all the
actions created.
By default there are already three arming actions:
Totale
[arm
"Perimetrali"
sectors], Disinserito [disarm all sectors], Parziale
[arm "Perimetrali" sector and disarm "Volumetrici"
sector].
Pressing the icon
Action.
Pressing the icon
settings, where you can change its properties.
Action Name: is the name with which the
Action is identified in all menus, notifications,
events, etc.
Type of Action:
✓ Arming
-
Operation on Sectors: No change [the
sector
keeps
Activate
Deactivate [the sector is disarmed].
✓ Relay control - Can be used for:
-
Shelly 1 / 1L
-
Shelly 2.5 (dual relay mode)
-
Shelly Plug S
✓ White light control - Can be used for:
-
Shelly RGBW2
-
Shelly Duo
-
Shelly Duo - RGBW
✓ RGB light control - Can be used for:
-
Shelly RGBW2
-
Shelly Duo - RGBW
operations
that
can
"Volumetrici"
and
(trash can) deletes the
(gear) you enter the Action
its
previous
[the
sector
is
be
state],
armed],