INSTALLATION
4
Circuit Breaker #1
L2
L1
BLACK
RED
WH-AZ011-M3(11KW) requires
1 breaker and 1 set of wires.
WH-AZ015-M3(15KW), WH-AZ018-M3(18KW)
requires 2 sets of breakers and wires.
WH-AZ021-M3(21KW), WH-AZ024-M3(24KW), WH-AZ027-M3(27KW) requires 3 sets
of breakers and wires.
Make sure the connection between the appliance and the breakers are correct.
5
Slide the panel from the top of the heater and push back to it's position. Secure the panel
with screws from the bottom.
ATTENTION
1.Make sure that the breaker is switched OFF before installing the wire to
avoid any danger of electric shock. All mounting and plumbing must be
completed before proceeding with electrical connection.
2.The heater must be connected to its own independent electrical circuit.
Install a fuse box or switch ("breaker") for exclusive use of the heater.
3.All unit must be connected to a properly grounded dedicated branch
circuit with proper voltage rating.
Circuit Breaker #2
L2'
L1'
BLACK
RED
Circuit Breaker #3
L2''
L1''
BLACK
RED
G
R
O
U
N
D
E
PG.13