Cascade 100G Manuale d'uso - Pagina 12

Sfoglia online o scarica il pdf Manuale d'uso per Carrelli elevatori Cascade 100G. Cascade 100G 16. Fork positioner

INSTALLATION
11
Adjust valve flow controls for equal
fork movement (if required)
NOTE: Attachment is Factory-adjusted for equal
fork movement when operated at recommended
pressure and flow rate.
A
Open forks fully, then close. Look for unequal
fork movement and note which cylinder is faster.
B
On faster fork (one that bottoms first), loosen
jam nut and screw flow control in (CW) 1/2-turn.
C
Repeat Step B until fork movement is equal.
Tighten jam nut.
12
Inspect fork hooks and carriage bars
NOTE: Use Go/No-Go Wear Gauge part no. 209560
(Class II) or 209561 (Class III).
A
Inspect the fork lower hooks and carriage bar.
If the gauge fits between the carriage bar and
lower hook, repair or replacement is needed.
B
Inspect the upper carriage bar. If the gauge
arrow touches the carriage bar, repair or
replacement is needed.
C
Inspect the fork upper hooks. If the gauge
arrow touches the hook, repair or replacement is
needed.
11
Left Fork
Right Fork
Flow Control
Flow Control
FORK LOWER HOOKS, CARRIAGE
Wear
Gauge
OK
UPPER CARRIAGE BAR
OK
FORK UPPER HOOKS
OK
Valve pressure
adjustment
FP0902.eps
FP0832.eps
6047782-R2 EN