13.0 Water Separator and Oil
Lubricator
Fill oil before using the cutter. REMEMBER, replenishing the
oil when the top of the oil can be seen in the glass (13.5). It
is important that the glass does not run out of oil, as this will
damage
the air motor and impair its performance.
Only use pneumatic oil (Part number: DCHY29307)
The filter (Part number P57106) in the water separator (13.4)
must be changed as necessary. In case of problems with the
3
2
4
1. Adjusting the mist lubricator
2. Air inlet from the compressor
3. Air outlet for the camera tank
air supply, clean the filter if necessary.
The mist lubricator must not be adjusted, as this has been
configured at the factory.The mist lubricator must be kept
upright during transport. If the fram is placed on its side, the
glass must
be removed to prevent oil flowing into the camera tank.
DURING transport with the device, always close the tap at the
air outlet for the camera tank.
4. Atomatic water separator
5. Oil tank
6. Air outlet for sluice
1
6
5
17