Danfoss 11101126 Manuale di installazione - Pagina 2

Sfoglia online o scarica il pdf Manuale di installazione per Controllore Danfoss 11101126. Danfoss 11101126 6. Intrinsically safe control

Refer to the following wiring diagrams for proper connections.
Wiring diagram for 11101116
Hazardous location
A
= 16.0 V
I = 110mA
P = 440mW
C = 0.4 µF
L = 0 mH
B
No adjustment is possible.
Do not attempt to disassemble or adjust the control.
For instructions on putting a pump with the Intrinsically Safe Control in service, refer to
Service
Manual,
Prior to installation, inspect packaging and unit for any damage. Do not continue installation if unit has visible signs of damage.
Danfoss is not responsible for the design of the control input circuit outside of the installed Mil-Spec connector. Proper design
on the entire system as noted in the applicable standards is required for safe usage in hazardous environments.
The EDC is designed to be controlled from a DC current source or voltage source. Pulse width modulation (PWM) is not required. But, if
a PMW signal is used, use a carrier frequency between 200 Hz and 4000 Hz. Do not use a pulse current of more than 120% of that
required for full output(refer to unit specifications below).
2
Non-hazardous location
.
Wiring diagram for 11101126, 11101118, 11101115, 11101106
Hazardous location
A
B
C
D
Exi Cl I, Div 1, Gp CD T4
Ex ia / AEx ia IIB T4 Ga
FM12ATEX0031X II 1 G Ex ia IIB T4 Ga
IECEx FMG 15.0008X Ex ia IIB T4 Ga
Initial Startup Procedure
Non-hazardou location
V = 8.6 V
I = 250mA
P = 537.5mW
C = 0.4 µF
L = 0 mH
V = 8.6 V
I = 250mA
P = 537.5mW
C = 0.4 µF
L = 0 mH
in the
Series 90 Pumps
© Danfoss A/S, 202