Quick Troubleshooting Guide
Note: To remove tubing from quick connect fittings, hold in on the
small collet ring at the end of the fitting, push this ring in towards
the fitting while gently pulling out on the tubing. This releases the
tubing from the fitting and it will slide out easily
Problem
Possible Cause
No Water Supply
Insufficient Pressure
GAC Filter Upside Down
Clogged filters
Fouled Membrane
No Water
Production*
Defective Check Valve
Defective Auto Shut Off
Defective Flow Restrictor
Obstruction In Line
Insufficient Pressure
Clogged filters
Fouled Membrane
Waste Water
Defective Check Valve
Runs
Defective Auto Shut Off
Constantly**
Defective Flow Restrictor
Obstruction In Line
Tank Not
No Pressure in Tank
Holding
Water***
Defective Check Valve
No Power
UV Bulb Not Lit
Bulb Burnt out
Transformer Defective
*Water output will decrease as the tank empties and will only be a quick drip or slow
stream when the tank is empty. This is normal.
**Water will run down the drain whenever the system is filling the tank. How long it
runs depends on water pressure, filter and membrane condition, membrane size,
system configuration, and amount of water taken from the tank. Average times for
refilling the tank range from 30-45 minutes for a couple glasses of water up to 4-5
hours to completely fill the tank.
***The standard tank will hold a maximum of about 3.2 gallons of water, the upgrade
tank will hold about a maximum of about 10.3 gallons of water. Actual storage capacity
may be less depending on system configuration and water pressure.
©2014 Abundant Flow Water Systems, Inc.
Solution
Ensure water supply is turned on
Use booster pump if pressure is <40psi
Single gasket needs to be facing up
Replace filters
Replace membrane
Replace check valve
Replace auto shut off valve
Replace flow restrictor
Ensure valves open & no kinks in lines
Trace flow of water to pinpoint cause
Use booster pump if pressure is <40psi
Replace filters
Replace membrane
Replace Check Valve
Replace auto shut off valve
Replace flow restrictor
Ensure valves open & no kinks in lines
Trace flow of water
Check pressure in tank, min.:4psi,
max.:10psi, with tank empty.
Replace check valve
Ensure transformer is plugged in and
verify outlet receives power
Replace Bulb—Replaced every 12
months, regardless of appearance
Transformer should output 125mA
23