Abundant Flow Water RF-MB-50F Manuale di risoluzione dei problemi
Sfoglia online o scarica il pdf Manuale di risoluzione dei problemi per Sistemi di filtrazione dell'acqua Abundant Flow Water RF-MB-50F. Abundant Flow Water RF-MB-50F 2. Zoi series mu pure system, reverse osmosis water filtration system & replacement filter set / replacement membrane
Troubleshooting
Note: To remove tubing from quick connect fittings, hold in on the small col-
let ring at the end of the fitting, push this ring in towards the fitting while
gently pulling out on the tubing. This releases the tubing from the fitting and
it will slide out easily
Quick Troubleshooting Guide
Problem
Possible Cause
No Water Supply
Insufficient Pressure
GAC Filter Upside Down
Clogged filters
Fouled Membrane
No Water Pro-
duction*
Defective Check Valve
Defective Auto Shut Off
Defective Flow Restrictor Replace flow restrictor
Obstruction In Line
Insufficient Pressure
Clogged filters
Fouled Membrane
Waste Water
Defective Check Valve
Runs Constant-
Defective Auto Shut Off
ly**
Defective Flow Restrictor Replace flow restrictor
Obstruction In Line
No Pressure in Tank
Tank Not Hold-
ing Water***
Defective Check Valve
*Water output will decrease as the tank empties and will only be a quick drip or slow
stream when the tank is empty. This is normal.
**Water will run down the drain whenever the system is filling the tank. How long it
runs depends on water pressure, filter and membrane condition, membrane size,
system configuration, and amount of water taken from the tank. Average times for
refilling the tank range from 30-45 minutes for a couple glasses of water up to 4-5
hours to completely fill the tank.
***The standard tank will hold a maximum of about 3.2 gallons of water, the up-
grade tank will hold about a maximum of about 10.3 gallons of water. Actual storage
capacity may be less depending on system configuration and water pressure.
Solution
Ensure water supply is turned on
Use booster pump if pressure is <40psi
Single gasket needs to be facing up
Replace filters
Replace membrane
Replace check valve
Replace auto shut off valve
Ensure valves open & no kinks in lines
Trace flow of water to pinpoint cause
Use booster pump if pressure is <40psi
Replace filters
Replace membrane
Replace Check Valve
Replace auto shut off valve
Ensure valves open & no kinks in lines
Trace flow of water
Check pressure in tank, min. pressure
4psi, max. pressure 10psi, with tank
empty.
Replace check valve
Zoi Series
Mu Pure System
Reverse Osmosis Water Filtration System
Replacement Filter Set
DFK-Mu
Typical Filter Life: 6-12 Months
Replacement Membrane
RF-MB-50F*
Typical Membrane Life: 2-4 Years
www.afwfilters.com
*Typical membrane used in most systems. Upgraded systems
may require a different membrane