Power Cord Replacement
General
Figure 8
The power cord is dressed along the side of the
Power Cord Routing
unit and exits at the rear (see Figure 8).
1. Disconnect unit from power source .
2. Remove the bottom cover.
3. Tag the wires and terminals and disconnect
them.
4. Remove the power cord from its retaining
clips.
5. Remove the power cord and its retainer ring
from the unit.
6. Pre-dress the new cord to determine
amount
of cord needed inside of the unit.
7. Knot the cord behind the retainer ring.
8. Install the new cord and retainer ring into
the
unit.
9. Dress the cord using the retaining clips.
10. Using the tags, reconnect the power cord to
the unit.
11. Install the bottom cover.
12. Plug unit into a GFI outlet.